A wireless meter removes the cable run and the mains supply with it. What it adds is a radio link that has to work from where the meter actually sits — a pit, a chamber, a basement plant room — and a battery that pays for every failed transmission.
All four are options on most of the range and the module is chosen per meter at order. The difference is not the radio standard — it is what has to exist on site before the first reading arrives.
| Uplink | Who owns the network | What it needs on site | Where it fits |
|---|---|---|---|
| LoRaWAN | Yours, via a gateway you own and maintain | A concentrator within radio range, with mains and backhaul | Sites and cities where a gateway already exists |
| NB-IoT | The mobile operator | Coverage at the pit; no gateway, nothing on site to power | Scattered chambers with no site network |
| 4G Cat.1 | The mobile operator | Coverage at the pit, same network as NB-IoT with more bandwidth | Fewer meters, or a payload beyond a reading |
| Wi-SUN | Yours, as a mesh | Nodes within radio range of each other | Where the utility already runs a Wi-SUN head end |
Confirmed in writing before the order: the uplink, the band or operator plan, the platform the readings must land in, and the reporting interval. Those four lines decide the configuration, and three of them cannot be changed at commissioning.
Is there a gateway on site — and will it still be maintained in five years?
LoRaWAN keeps the data on your own network and removes the subscription. It is the cheaper route to run, and the one that fails when the concentrator is forgotten rather than when the operator changes a tariff.
NB-IoT reaches the operator's network directly: no concentrator to power, no backhaul to arrange, nothing on site to fail. The constraint moves to coverage at the pit, which is why the survey comes before the order.
4G Cat.1 sits on the same licensed network as NB-IoT with more bandwidth for the payload. The trade is drawn current, so the interval and the battery figure have to be agreed together rather than separately. Wi-SUN is a mesh: confirm the module and profile against the head end you already run before it goes on a specification.
The published figures assume a normal reporting cycle at 25 ± 5 °C. Everything below moves the number, and two of the three are outside the meter.
All four are cheaper to check now than after the pit is closed.
A plant room with mains and a short run to a PLC does not need a battery, a module or a subscription. Wired is cheaper to own where the cable is already there.
The same body is built with different modules. What changes the decision is the chamber, the cover and what already exists upstream.
We will come back with one recommended model, the wiring diagram and a quotation — not a 40-page catalogue.