Industrial · Valve-free

DN80 In-line Flanged Ultrasonic Water Meter

A bulk meter built like pipework, not like an instrument. One-piece cast metal body with the flanges machined into it, a straight-through bore with nothing inside to clog, and brass caps over sealed transducer pockets you can actually inspect.

DN80 (3")Nominal size
NB-IoT + ModbusUplink + local bus
Valve-freeStraight-through bore
Low powerBattery operation

OEM / ODM options →

  • Flanged both ends — bolts into an existing DN80 pipe spool
  • Straight-through tube: no valve, no impeller, pressure loss stays low
  • Gland-sealed cable entry and tamper seal on the cover
  • Reads without mains power — data leaves the pit over the mobile network
Specification

Technical data


Body is cast metal with a black coating; the flange drill can be matched to your pipe standard on request. Flow range and Modbus register map are confirmed at order.

Nominal sizeDN80 (3")
TypeUltrasonic, in-line
ConnectionFlanged, both ends
BodyCast metal, black coated; flanges machined into a single body
Measuring tubeStraight-through bore, no moving measuring parts
Transducer portsBrass-capped, sealed sensor pockets
ValveNone — valve-free
CommunicationNB-IoT uplink + Modbus (RS-485) local bus
Data pathsNB-IoT → cloud / app; Modbus → PLC / SCADA
PowerLow-power design, battery operation, no mains run required
MediumWater
SealingSealed housing, gland-sealed cable entry, tamper seal fitted
Engineering detail

What you can check with your own eyes


Most bulk meter failures are mechanical or sealing failures, and both are invisible on a datasheet. These are the details we build in — and the ones you can verify before the order.

One-piece cast metal body with machined flanges and brass-capped ports
One-piece cast body. Flanges are machined into a single casting, so the body stays rigid under surge and there is no threaded joint to strip. Brass caps close the ultrasonic sensor cavities.
Straight-through measuring tube with no moving parts
Nothing inside to wear out. A straight-through bore with no valve and no impeller: nothing to clog, pressure loss stays low, and ultrasonic sensing happens through the tube wall.
Brass-capped port, gland-sealed entry and tamper seal
Sealed where water enters. Brass-capped ports, a locked cable gland and a red tamper seal — so a housing that has been opened leaves evidence.
NB-IoT uplink and Modbus local bus on the DN80 meter
NB-IoT uplink, Modbus at the panel. Wireless data goes to the cloud or app; the wired bus feeds a PLC or SCADA locally. Low-power electronics mean no mains cable into the pit.
DN80 ultrasonic meter installed in a buried chamber
Application

Buried chambers, still readable

A chamber that fills after rain is the normal case, not the exception. The DN80 is sealed for it, runs on its own battery, and reports over the mobile network — so the reading comes to the office instead of requiring a visit with a key and a torch.

  • Sealed housing and low-power design for pits without power
  • No power cable run into the chamber
  • Flanged body fits the existing pipe run — faster commissioning
DN80 ultrasonic water meter on an industrial plant water line
Application

Plant water lines

Process water, cooling make-up, wash-down: the DN80 gives a consumption figure and a process reading from the same device, with the wired output going straight to the control room.

  • Flanged in-line body, DN80 — bolts into an existing pipe spool
  • Modbus output for PLC / SCADA integration
  • Consumption data and process reading from one meter
Installation & OEM

Fits your line. Wears your label.

The DN80 flange pattern drops straight into a DN80 pipe run, which shortens commissioning. For distributors and utilities, the cover, dial, label and packaging can carry your brand, and the Modbus map can be aligned to your existing head-end.

DN80 flange pattern Drops into DN80 pipe Faster commissioning OEM / ODM on request
DN80 meter flange pattern for direct pipe installation
Questions we get asked

Before you specify


No — isolation belongs on a separate valve in the line. Removing the valve from the meter keeps the bore straight, reduces pressure loss and removes a wear item from the device you cannot easily service.

Yes. The wired Modbus output and the NB-IoT uplink are configured independently, so a plant installation can ship with the local bus alone.

Tell us the standard and pressure rating your pipe uses and we machine the flange to match. The body is a single casting, so the drill pattern is set at production, not by an adapter.

The current DN80 body is 3". For larger diameters or different pressure classes, send the requirement — the platform is built to be extended, and we will confirm what is feasible before quoting.

Next step

Get the DN80 drawing and quotation

Send the pipe standard, pressure rating, flow range and whether you need NB-IoT, Modbus or both. You get the dimension drawing and pricing in one reply.

Choose your language