“Smart” is used for a meter with a pulse output and for one that reports to a head end on its own. They are not the same purchase. A meter is smart to the extent that it does three jobs without a person walking to it: measure electronically, carry the reading off site, and act on what it measured.
Skip any one of them and the meter still measures — it just stops being a remote meter. This is the part worth pinning down before a specification is written.
| Layer | What it means here | What you lose without it |
|---|---|---|
| Measure | Transit-time ultrasonic, or a non-magnetic register read without magnetic coupling. Nothing in the water path to wear. | The reading drifts as an impeller and gear train wear, and grit or scale jams the register. |
| Transmit | LoRaWAN, NB-IoT, 4G Cat.1 or Wi-SUN over the air; RS-485, M-Bus, Modbus or pulse on a cable. | Somebody has to walk to the meter — every month, for the life of the installation. |
| Control | An integrated ball valve on a gear motor, open or closed under 10 s, rated for 5,000+ cycles. | Every disconnection or reconnection is a site visit with a key and a tamper window. |
| Keep | 24 months of monthly totals, 100 daily totals and 100 alarms held in the register; totals survive a power loss. | The reading exists only in the last successful upload, and an outage becomes missing consumption. |
Class 2 is Class 2, smart or not. What the electronics change is the low-flow end — the R ratio — and whether the reading arrives without a visit. Those are two separate decisions and are better written as two lines in the specification.
Not every model does all three. The table is the honest version — read the row before the model code goes into a tender.
| Family | Measurement | Uplink as specified | Control |
|---|---|---|---|
| DN15 LoRaWAN ultrasonic | Transit-time | LoRaWAN / NB-IoT / 4G Cat.1 / Wi-SUN | None — valveless |
| XY-15 / XY-20 | Transit-time | LoRaWAN / NB-IoT / 4G Cat.1 / Wi-SUN | Integrated ball valve, under 10 s |
| LXSY-15 / 20 / 25 | Non-magnetic register | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Optional valve control |
| LXCY-32~50 | 4-channel transit-time | LoRaWAN / NB-IoT | Optional |
| DN50 flanged | Transit-time | LoRaWAN 915 MHz | None |
| DN80 in-line | Transit-time | NB-IoT uplink + Modbus | None — valve-free bore |
Sizes above DN80 are built to the same three layers but specified per project — the flow parameters, flange drilling and uplink are fixed at the specification step rather than taken from a catalogue row.
An alarm is only worth wiring if it names something an operator can act on. These five are reported by the register, and each one maps to a different job.
A ten-year number is not a property of the cell. It is the cell divided by an upload schedule, and it moves when the schedule or the radio conditions move. Ask for both numbers together, in writing.
| Family | Published battery figure | What the figure is quoted against |
|---|---|---|
| XY-15 / XY-20 valve control | 10+ years, 3.6 V Li-SOCl₂ | The pack is sized for a daily upload with the valve idle |
| LXCY-32~50 bulk | ≥ 8 years, 3.6 V lithium | Longer radio path, larger body |
| LXSY-15 / 20 / 25 | ≥ 6 years, 3.6 V lithium | Daily reporting on the non-magnetic register |
| DN15 ultrasonic | Per configuration | Quoted against the interval you specify |
The same hardware is bought for different reasons, and the reason decides which layer of “smart” actually matters.
A daily read removes the walking route; the valve removes the disconnection visit. On this account the control layer earns its price, and leakage is the alarm that matters.
Meters sit at zone and building boundaries. Here the measurement and the uplink matter and the valve usually does not — the useful output is a night-flow figure that is comparable month to month.
No mains run into the pit, so everything is battery and radio. The meter has to survive the water and the enclosure has to let the radio out — those are two different problems.
A non-magnetic register is read without magnetic coupling, so a magnet held to the cover does nothing. That is a revenue-protection decision rather than a metering one.
The uplink choice, the size and the price are each a separate decision. Take them in that order.
LoRaWAN, NB-IoT, 4G Cat.1 and Wi-SUN side by side: what each needs on site and who owns the network.
Compare the uplinks →Why a smart meter sized on a peak flow reads zero at three in the morning, with the published Q3 values.
Read the sizing guide →We will come back with one recommended model, the wiring diagram and a quotation — not a 40-page catalogue.
Choose your language
Interface translated. Technical documents stay in English.