A transit-time ultrasonic meter for residential and light-commercial lines from DN15 to DN50. No moving parts in the water path, Class 2 accuracy that holds at low flow, IP68 sealing, and one communication module pre-installed per meter — RS485 / M-BUS, or 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN.

Two transducers send ultrasonic pulses with and against the flow. The difference in travel time gives the velocity, and the meter integrates it into volume — in both directions, so backflow and tampering are metered rather than hidden.
| Measuring principle | Transit-time ultrasonic, bidirectional; single-channel for DN≤40 |
|---|---|
| Accuracy | Class 2, designed and manufactured to ISO 4064; factory inspection to ISO/IEC 17025 |
| Range ratio | R200 on DN15–DN25; R400 on DN32–DN50. R80 / 100 / 160 / 315 / 400 / 500 on DN15–DN25 and R160 / 315 / 500 / 630 on DN32–DN50 by custom order |
| Body materials | Stainless steel, brass or engineering plastic (DN15–DN25); stainless steel, copper or engineering plastic (DN32–DN50) |
| Installation | Horizontal or vertical, no accuracy loss; flow-field sensitivity U0/D0 — no straight-pipe run required under normal conditions |
| Sealing | IP68, whole meter — it can stay submerged |
| Alarms | Leak, reverse flow, tampering, damaged electronic seal, empty pipe, low battery, abnormal water temperature, transducer fault |
Values as published in the LXCY-15~25 and LXCY-32~50 manuals. Q4 is the overload flow the meter must survive briefly, Q3 the rated flow, Q1 the minimum flow inside the accuracy band.
| Nominal bore | Q4 m³/h | Q3 m³/h |
Q2 L/h | Q1 L/h | R Q3/Q1 | Temp class |
|---|---|---|---|---|---|---|
| DN15 | 3.125 | 2.5 | 20 | 12.5 | 200 | T30 / T50 / T70 |
| DN20 | 5.000 | 4.0 | 32 | 20 | 200 | T30 / T50 / T70 |
| DN25 | 7.875 | 6.3 | 50.4 | 25.2 | 200 | T30 / T50 / T70 |
| DN32 | 12.5 | 10.0 | 40 | 25 | 400 | T30 / T50 |
| DN40 | 20.0 | 16.0 | 64 | 40 | 400 | T30 / T50 |
| DN50 | 31.25 | 25.0 | 100 | 62.5 | 400 | T30 / T50 |
Maximum permissible error: ±5% in the low zone (Q1 ≤ Q < Q2); ±2% in the high zone (Q2 ≤ Q ≤ Q4) on DN15–DN25, and ±2% between 0.1 °C and 30 °C / ±3% above 30 °C on DN32–DN50.
DN50 is also built as a flanged meter in the LXCY-50~300 series — choose the connection you already have in the line.
If the line needs a wider Q1 than R400 gives, the same body is available at R250 and R200. Only Q2 and Q1 move; Q3 and Q4 stay as listed above.
| Bore | R | Q2 L/h | Q1 L/h |
|---|---|---|---|
| DN32 | 250 | 64.0 | 40.0 |
| DN32 | 200 | 80.0 | 50.0 |
| DN40 | 250 | 102.4 | 64.0 |
| DN40 | 200 | 128.0 | 80.0 |
| DN50 | 250 | 160.0 | 100.0 |
| DN50 | 200 | 200.0 | 125.0 |
| Parameter | DN15–DN25 | DN32–DN50 |
|---|---|---|
| Accuracy class | Class 2 | Class 2 |
| Temperature class | T30 / T50 / T70 | T30 / T50 |
| Operating temperature | -25 °C to +55 °C (other ranges on request) | -25 °C to +55 °C |
| Storage temperature | — | -25 °C to +55 °C |
| Relative humidity | ≤100 % RH (condensing version on request) | — |
| Protection grade | IP68 | IP68 |
| Working pressure | 1.0 MPa (PN10) standard; 1.6 MPa optional; 2.5 MPa on request | 1.6 MPa (PN16) |
| Pressure loss class | Δp40 | Δp40 |
| Environment class | Class O | Class O |
| EMC class | E2 | E2 |
| Reverse flow | Measured and totalled | Measured and totalled |
Every meter leaves the factory with a single communication module fitted. Wired and wireless builds share the same register and the same alarm set.
| Power supply | 3.6 V DC lithium battery |
|---|---|
| Battery life | ≥8 years on timed upload (reading every 20 min, upload every 12 h). The DN15–DN25 manual also states up to 10 years at 25 ±5 °C; expect less in weak-signal sites or at high alarm frequency. |
| Current consumption | Sleep ≤18 µA; standby ≤1.8 mA; peak transmit ≤210 mA (DN15–DN25) |
| Wired interfaces | RS-485 / M-BUS |
| Wireless interfaces | 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN |
| Local interface | Infrared port for on-site parameter setting and read-out |
| Display | 9-digit LCD with function symbols; cumulative flow, instantaneous flow, water temperature, operating hours, date/time, meter ID, software version, alarm code |
| Resolution | Cumulative flow 0.0001 m³; instantaneous flow 0.0001 m³/h; temperature 0.01 °C |
| Totalising range | 0 – 999,999.999 m³ |
| Data retention | Historical data kept more than 10 years after power loss |
| Remote functions | Remote configuration, firmware update, scheduled upload, alarm push through the utility platform |
L is the meter body; L1 includes the standard union tailpieces and is the length to reserve in the line. All figures in millimetres.
| Bore | L | L1 | H | W | S | Meter thread | Union thread |
|---|---|---|---|---|---|---|---|
| DN15 | 125 | 165 | 112 | 75 | 45 | G3/4B | R1/2 |
| DN20 | 125 | 195 | 118 | 75 | 51 | G1B | R3/4 |
| DN25 | 168 | 225 | 120 | 75 | 59 | G1¼B | R1 |
| Bore | L | L1 | W | H | H1 | Thread |
|---|---|---|---|---|---|---|
| DN32 | 230 | 350 | 96 | 125 | 212 | G1½B |
| DN40 | 245 | 376 | 96 | 134 | 221 | G2B |
| DN50 | 300 | 410 | 96 | 138 | 225 | G2½B |
H1 is the overall height including the register. Dimensions are nominal and subject to normal casting tolerance — ask for the drawing before you cut pipe.
Five details decide the build. Send them together and the quotation comes back with a drawing, not with questions.
| Bore | DN15, 20, 25, 32, 40 or 50 — or the flow range you need to cover, and we will size it |
|---|---|
| Ratio | R200 on DN15–DN25 or R400 on DN32–DN50 as standard; R250 / R200 on DN32–DN50; other ratios by custom order |
| Communication | RS485, M-BUS, 2G, 4G Cat.1, NB-IoT, LoRaWAN or Wi-SUN — one module per meter |
| Body | Stainless steel, brass or engineering plastic; pressure rating PN10 / PN16 / PN25 |
| Temperature | Cold water T30, T50, or hot water T70 (DN15–DN25) |
No. Flow-field sensitivity is U0/D0, so under normal conditions no straight-pipe run is required, and the meter installs horizontally or vertically without accuracy loss.
R200 on DN15–DN25 and R400 on DN32–DN50 as standard. R80, R100, R160, R315, R400 and R500 are available on DN15–DN25, and R160, R315, R500 and R630 on DN32–DN50; other ratios are a custom order.
Eight years or more on the stated duty — a reading every 20 minutes and an upload every 12 hours. The DN15–DN25 manual also states up to 10 years at 25 ±5 °C, so the figure moves with the upload interval you configure.
Yes. The whole meter is IP68, so it can stay submerged. Historical data is retained for more than 10 years after a power loss, so an interruption does not reset the register.