Large-diameter ultrasonic · DN50–DN150

DN65 Two-Channel Ultrasonic Water Flow Meter

A ultrasonic water meter built as a flanged pipe section for district metering and plant rooms. Two transit-time paths average the velocity profile, so the reading holds on a real main. Rated Q3 40 m³/h, accuracy class 2 to ISO 4064, R400, 1.6 MPa carbon steel body, IP68 down to the cable gland, and one communication module per meter — LoRaWAN, NB-IoT, 4G or RS485.

DN65 Q3 40 m³/h Class 2 ISO 4064 R400 range ratio IP68 whole meter Two-channel transit-time
DN65 two-channel ultrasonic water meter, black carbon steel flanged body with brass transducer ports and tamper-proof seals
DN65, flanged — DN50–DN150 share the same architecture
How it measures

Two paths, one measurement


Two transducers face each other across the measuring tube and fire alternately, upstream and downstream. The difference in transit time between the two directions is proportional to flow velocity, and the meter converts it to volume. There are no moving parts in the water path, so wear, grit and low flow do not erode the reading over time the way they do in a mechanical meter.

Two chords are enough when the meter sits on a straight run with a settled velocity profile. Where the meter lands close to a bend, a pump or a partly closed valve, the four-channel LXCY-50~300 is the better choice — it averages four paths and holds accuracy through the disturbance.

Diagram of two-channel ultrasonic measurement: transducer pair across a measuring tube, flow measured by transit-time difference
Transit-time difference between the upstream and downstream path gives flow velocity; the tube cross-section turns it into volume.
Measuring principleTransit-time ultrasonic, two-channel, bi-directional
AccuracyClass 2 to ISO 4064; factory verification traceable to a CNAS-accredited laboratory
Range ratioR250 / R400 / R500; R400 is the standard configuration
Measuring mediumWater and homogeneous liquids
BodyCarbon steel pipe section, brass transducer ports, protective coating inside and out
InstallationAny orientation; low straight-pipe demand compared with a mechanical meter
SealingIP68, whole meter including the cable gland
Flow parameters

Capacity by bore


Q3 is the rated permanent flow, Q4 the overload flow the meter must survive briefly, Q1 the bottom of the accuracy band. Q4 and Q3 do not change with the range ratio — only Q1 moves, because the ratio sets how deep the meter still measures.

ModelQ4
m³/h
Q3
m³/h
Q1 at R400
L/h
Q1 at R250
L/h
DN5031.2525.062.5100.0
DN6550.040.0100.0160.0
DN8078.7563.0157.5252.0
DN100125.0100.0250.0400.0
DN125200.0160.0400.0640.0
DN150312.5250.0625.01000.0

Q1 follows the ratio you order: Q3 ÷ 400 for R400, Q3 ÷ 250 for R250, Q3 ÷ 500 for R500, with Q2 = 1.6 × Q1 as set by ISO 4064. The quotation states Q1 and Q2 for the bore and ratio you specify.

Maximum permissible error: ±2 % between 0.1 °C and 30 °C, ±3 % above 30 °C, across Q2 ≤ Q ≤ Q4.

Build

Carbon steel body, brass ports, IP68 everywhere


The pipe section is carbon steel with a protective coating inside and out, so it drops into a buried chamber without a separate corrosion allowance. The transducer ports are brass, machined and sealed individually — if one transducer is ever replaced on site, the other three seals stay untouched.

Carbon steel pipe section with brass transducer ports, IP68 housing and protective coating, with a close-up of the brass port
Carbon steel pipe section, brass transducer ports and a protective coating on the water side and the outside.
Close-up of the four-hole DN65 flange, IP68 cable gland and tamper-proof seal
Four-hole flange, IP68 cable gland and the tamper-proof seal on the register cover.
Pressure rating1.6 MPa (PN16) as standard; state the line rating if higher
Pressure loss0.01 MPa at rated flow
Temperature classT30 as standard; T50 or T70 by order
Ambient temperature−25 to +55 °C
Protection gradeIP68, whole meter
ConnectionFlanged, four-hole; drilling to your standard stated at order — certified drawings issued for approval before production
Tamper protectionSealed register cover, tamper alarm logged in the event record
Electronics & communication

Readings without walking the route


One communication module per meter, fitted at the factory and configured before shipment. The register keeps counting and logging whether or not the network is reachable, so a gap in coverage costs you readings, never volume.

LoRaWAN data path from the water meter through a gateway to a cloud platform and utility dashboard
Meter to gateway to cloud, with the utility dashboard at the end of the chain.
WirelessLoRaWAN, NB-IoT, 4G (Cat.1)
WiredRS485
ProtocolModbus RTU, CJ/T-188; custom frame on request
Local interfaceInfrared port for on-site reading and parameter setting
DisplayLCD, 9 + 5 digits
Power supply3.6 V lithium battery; service life depends on the reading and upload interval
AlarmsEmpty pipe, reverse flow, leakage, low battery, transducer fault, tamper
Where it goes

District mains, plant rooms, wet pits


DN65 sits at the size where a building or a sub-network meets the distribution main. The two applications below are where most of these meters end up; both were photographed on real installations, not in a studio.

DN65 ultrasonic water meter installed between gate valves on a district metering bulk supply line
District metering: bulk supply and sub-network measurement, flanged straight into the line.
DN65 ultrasonic water meter fitted on a plant room supply line beside pumps, showing bi-directional flow
Plant room supply lines: bi-directional flow where pipe space is tight.
District meteringBulk supply and sub-network measurement; reverse flow totalled separately for leak and backflow analysis
Plant roomsBuilding supply and process lines; measuring direction is set at commissioning
Wet pits and buried chambersIP68 sealing, no venting required, register readable without opening the chamber
Irrigation and bulk transferHomogeneous water without entrained air; install with the tube full
Measuring range

R400 from low flow to full flow


At R400 the meter still measures down to Q3 ÷ 400, so a DN65 keeps reading at night-time leakage levels that a mechanical meter of the same size would miss entirely. That is the point of the wide ratio on a district main: you see the small flows, not just the busy ones.

R400 measuring range diagram showing class 2 accuracy and bi-directional measurement across low flow to full flow
R400 covers the band from starting flow to overload; measurement is bi-directional across the whole range.

Q1 for DN65 is 100 L/h at R400 and 160 L/h at R250. Choose R250 when you want the widest turndown the meter can hold at full accuracy under ISO 4064 without paying for the tighter bottom end; choose R400 when leakage detection at night matters as much as billing.

Calibration

Every meter goes on the bench


Each meter is wet-calibrated against a reference before it leaves the workshop, and the protocol is configured and tested on the same bench — not left for the installer to discover at commissioning.

DN65 ultrasonic water meter on the factory calibration bench with reference meters and control cabinet in the background
Bench testing and protocol configuration in our own workshop, on the same line that builds the meter.
CalibrationWet calibration against a reference meter on every unit; certificate supplied with the shipment
TraceabilityCarried out in a CNAS L25773 accredited laboratory
Protocol testFrame tested on the bench before packing for Modbus RTU, CJ/T-188 or the custom frame you specify
RejectionUnits outside the class 2 band do not ship; they are re-calibrated or scrapped, not downgraded
Data sheet

DN65 at a glance


ModelTwo-channel ultrasonic water meter, DN65 (family DN50–DN150)
Nominal diameterDN65; DN50, DN80, DN100, DN125 and DN150 share the same architecture
Rated flow Q340 m³/h
Overload flow Q450 m³/h
Accuracy classClass 2 to ISO 4064
Range ratioR400 standard; R250 and R500 by order
Temperature classT30 standard; T50 and T70 by order
Working pressure1.6 MPa
Pressure loss0.01 MPa
ProtectionIP68
DisplayLCD, 9 + 5 digits
CommunicationLoRaWAN / NB-IoT / 4G / RS485
ProtocolModbus RTU, CJ/T-188, custom
Power3.6 V lithium battery
OEMYour brand on the dial, the register and the packaging; see OEM / ODM
Technical specification sheet for the DN65 ultrasonic water meter: nominal diameter, accuracy class, dynamic range, pressure, temperature class, protection class, communication and power supply
The same data as a one-page sheet, if you need to forward it internally.
Ordering

What to specify


Five answers turn a quotation into a build sheet.

BoreDN65, or another size in the DN50–DN150 family — give us peak and minimum flow and we will size it
RatioR400 as standard; R250 or R500 if your tariff or leakage programme needs a different bottom end
CommunicationLoRaWAN, NB-IoT, 4G or RS485 — one module per meter; state the platform and the frame it must speak
ConnectionFlange drilling standard and face-to-face if it must match an existing spool
MarkingYour logo, dial layout and packaging for OEM; approval drawing issued before production

Where DN65 sits inside the wider DN50–DN300 range, and how the straight-pipe, stored-data and ultrasonic-versus-mechanical questions are answered across it, is covered in the bulk ultrasonic meter guide.

Questions buyers ask

DN65 ultrasonic meter FAQ


Q3, the rated permanent flow, is 40 m³/h. Q4, the overload flow the meter must survive briefly, is 50 m³/h. Q1, the bottom of the accuracy band, is 100 L/h at R400 or 160 L/h at R250.

Two chords are enough on a straight run with a settled velocity profile, and they keep the body shorter and the price lower. Downstream of a bend, a pump or a partly closed valve, the velocity profile is skewed; that is where the four-channel LXCY-50~300 earns its price.

Yes. Measurement is bi-directional, reverse volume is totalled separately, and a reverse-flow alarm can be configured for the network.

Yes. The meter is sealed to IP68 as a whole unit, including the cable gland and the register housing, so a wet pit is a normal installation rather than a special order.

CE status is configuration-specific. The EMC verification we hold covers the LXSY-15, LXSY-20 and LXSY-25 meters. For a DN65 ultrasonic meter we state the applicable directive in the quotation and supply the documentation that matches the exact model you receive, rather than a blanket claim that may not apply to your configuration.

Class 2 under the current ISO 4064 edition — that is what the nameplate and the test report state. Class A, B and C come from earlier editions of the standard. If your national metrology authority still references Class B, tell us at order and we confirm the test report against that requirement.

Yes — dial, register, nameplate and packaging. Tooling, SMT, calibration and assembly stay in-house, so there is no subcontractor between your brand and the line. See OEM / ODM for the full scope.