Not sure this is the right bore? Work it out from your peak and minimum flow — the sizing calculator needs two numbers.
A ultrasonic water meter built as a flanged pipe section for district metering and plant rooms. Two transit-time paths average the velocity profile, so the reading holds on a real main. Rated Q3 40 m³/h, accuracy class 2 to ISO 4064, R400, 1.6 MPa carbon steel body, IP68 down to the cable gland, and one communication module per meter — LoRaWAN, NB-IoT, 4G or RS485.

Two transducers face each other across the measuring tube and fire alternately, upstream and downstream. The difference in transit time between the two directions is proportional to flow velocity, and the meter converts it to volume. There are no moving parts in the water path, so wear, grit and low flow do not erode the reading over time the way they do in a mechanical meter.
Two chords are enough when the meter sits on a straight run with a settled velocity profile. Where the meter lands close to a bend, a pump or a partly closed valve, the four-channel LXCY-50~300 is the better choice — it averages four paths and holds accuracy through the disturbance.

| Measuring principle | Transit-time ultrasonic, two-channel, bi-directional |
|---|---|
| Accuracy | Class 2 to ISO 4064; factory verification traceable to a CNAS-accredited laboratory |
| Range ratio | R250 / R400 / R500; R400 is the standard configuration |
| Measuring medium | Water and homogeneous liquids |
| Body | Carbon steel pipe section, brass transducer ports, protective coating inside and out |
| Installation | Any orientation; low straight-pipe demand compared with a mechanical meter |
| Sealing | IP68, whole meter including the cable gland |
Q3 is the rated permanent flow, Q4 the overload flow the meter must survive briefly, Q1 the bottom of the accuracy band. Q4 and Q3 do not change with the range ratio — only Q1 moves, because the ratio sets how deep the meter still measures.
| Model | Q4 m³/h | Q3 m³/h | Q1 at R400 L/h | Q1 at R250 L/h |
|---|---|---|---|---|
| DN50 | 31.25 | 25.0 | 62.5 | 100.0 |
| DN65 | 50.0 | 40.0 | 100.0 | 160.0 |
| DN80 | 78.75 | 63.0 | 157.5 | 252.0 |
| DN100 | 125.0 | 100.0 | 250.0 | 400.0 |
| DN125 | 200.0 | 160.0 | 400.0 | 640.0 |
| DN150 | 312.5 | 250.0 | 625.0 | 1000.0 |
Q1 follows the ratio you order: Q3 ÷ 400 for R400, Q3 ÷ 250 for R250, Q3 ÷ 500 for R500, with Q2 = 1.6 × Q1 as set by ISO 4064. The quotation states Q1 and Q2 for the bore and ratio you specify.
Maximum permissible error: ±2 % between 0.1 °C and 30 °C, ±3 % above 30 °C, across Q2 ≤ Q ≤ Q4.
The pipe section is carbon steel with a protective coating inside and out, so it drops into a buried chamber without a separate corrosion allowance. The transducer ports are brass, machined and sealed individually — if one transducer is ever replaced on site, the other three seals stay untouched.


| Pressure rating | 1.6 MPa (PN16) as standard; state the line rating if higher |
|---|---|
| Pressure loss | 0.01 MPa at rated flow |
| Temperature class | T30 as standard; T50 or T70 by order |
| Ambient temperature | −25 to +55 °C |
| Protection grade | IP68, whole meter |
| Connection | Flanged, four-hole; drilling to your standard stated at order — certified drawings issued for approval before production |
| Tamper protection | Sealed register cover, tamper alarm logged in the event record |
One communication module per meter, fitted at the factory and configured before shipment. The register keeps counting and logging whether or not the network is reachable, so a gap in coverage costs you readings, never volume.

| Wireless | LoRaWAN, NB-IoT, 4G (Cat.1) |
|---|---|
| Wired | RS485 |
| Protocol | Modbus RTU, CJ/T-188; custom frame on request |
| Local interface | Infrared port for on-site reading and parameter setting |
| Display | LCD, 9 + 5 digits |
| Power supply | 3.6 V lithium battery; service life depends on the reading and upload interval |
| Alarms | Empty pipe, reverse flow, leakage, low battery, transducer fault, tamper |
DN65 sits at the size where a building or a sub-network meets the distribution main. The two applications below are where most of these meters end up; both were photographed on real installations, not in a studio.


| District metering | Bulk supply and sub-network measurement; reverse flow totalled separately for leak and backflow analysis |
|---|---|
| Plant rooms | Building supply and process lines; measuring direction is set at commissioning |
| Wet pits and buried chambers | IP68 sealing, no venting required, register readable without opening the chamber |
| Irrigation and bulk transfer | Homogeneous water without entrained air; install with the tube full |
At R400 the meter still measures down to Q3 ÷ 400, so a DN65 keeps reading at night-time leakage levels that a mechanical meter of the same size would miss entirely. That is the point of the wide ratio on a district main: you see the small flows, not just the busy ones.

Q1 for DN65 is 100 L/h at R400 and 160 L/h at R250. Choose R250 when you want the widest turndown the meter can hold at full accuracy under ISO 4064 without paying for the tighter bottom end; choose R400 when leakage detection at night matters as much as billing.
Each meter is wet-calibrated against a reference before it leaves the workshop, and the protocol is configured and tested on the same bench — not left for the installer to discover at commissioning.

| Calibration | Wet calibration against a reference meter on every unit; certificate supplied with the shipment |
|---|---|
| Traceability | Carried out in a CNAS L25773 accredited laboratory |
| Protocol test | Frame tested on the bench before packing for Modbus RTU, CJ/T-188 or the custom frame you specify |
| Rejection | Units outside the class 2 band do not ship; they are re-calibrated or scrapped, not downgraded |
| Model | Two-channel ultrasonic water meter, DN65 (family DN50–DN150) |
|---|---|
| Nominal diameter | DN65; DN50, DN80, DN100, DN125 and DN150 share the same architecture |
| Rated flow Q3 | 40 m³/h |
| Overload flow Q4 | 50 m³/h |
| Accuracy class | Class 2 to ISO 4064 |
| Range ratio | R400 standard; R250 and R500 by order |
| Temperature class | T30 standard; T50 and T70 by order |
| Working pressure | 1.6 MPa |
| Pressure loss | 0.01 MPa |
| Protection | IP68 |
| Display | LCD, 9 + 5 digits |
| Communication | LoRaWAN / NB-IoT / 4G / RS485 |
| Protocol | Modbus RTU, CJ/T-188, custom |
| Power | 3.6 V lithium battery |
| OEM | Your brand on the dial, the register and the packaging; see OEM / ODM |

Five answers turn a quotation into a build sheet.
| Bore | DN65, or another size in the DN50–DN150 family — give us peak and minimum flow and we will size it |
|---|---|
| Ratio | R400 as standard; R250 or R500 if your tariff or leakage programme needs a different bottom end |
| Communication | LoRaWAN, NB-IoT, 4G or RS485 — one module per meter; state the platform and the frame it must speak |
| Connection | Flange drilling standard and face-to-face if it must match an existing spool |
| Marking | Your logo, dial layout and packaging for OEM; approval drawing issued before production |
Where DN65 sits inside the wider DN50–DN300 range, and how the straight-pipe, stored-data and ultrasonic-versus-mechanical questions are answered across it, is covered in the bulk ultrasonic meter guide.
Q3, the rated permanent flow, is 40 m³/h. Q4, the overload flow the meter must survive briefly, is 50 m³/h. Q1, the bottom of the accuracy band, is 100 L/h at R400 or 160 L/h at R250.
Two chords are enough on a straight run with a settled velocity profile, and they keep the body shorter and the price lower. Downstream of a bend, a pump or a partly closed valve, the velocity profile is skewed; that is where the four-channel LXCY-50~300 earns its price.
Yes. Measurement is bi-directional, reverse volume is totalled separately, and a reverse-flow alarm can be configured for the network.
Yes. The meter is sealed to IP68 as a whole unit, including the cable gland and the register housing, so a wet pit is a normal installation rather than a special order.
CE status is configuration-specific. The EMC verification we hold covers the LXSY-15, LXSY-20 and LXSY-25 meters. For a DN65 ultrasonic meter we state the applicable directive in the quotation and supply the documentation that matches the exact model you receive, rather than a blanket claim that may not apply to your configuration.
Class 2 under the current ISO 4064 edition — that is what the nameplate and the test report state. Class A, B and C come from earlier editions of the standard. If your national metrology authority still references Class B, tell us at order and we confirm the test report against that requirement.
Yes — dial, register, nameplate and packaging. Tooling, SMT, calibration and assembly stay in-house, so there is no subcontractor between your brand and the line. See OEM / ODM for the full scope.
Interface translated. Technical documents stay in English.