Once a meter moves onto a main — a trunk main, a DMA inlet, a plant header — the questions stop being about the domestic customer and start being about reconciliation: does this reading survive a flood, a power cut, a flow that swings from night leakage to fire-flow demand, and an audit five years from now? These nine questions are the ones that come up in every bulk project we quote.
- Bulk ultrasonic meters are built as a flanged pipe section from DN50 to DN300, for main-line metering rather than service connections.
- They hold ISO 4064 / OIML R49 compliance at Class 2, with an R160 range ratio so the low end of the night flow is still inside the accuracy band.
- Wired M-Bus, RS485 and pulse outputs, plus LoRaWAN, NB-IoT, 4G, wM-Bus and Sigfox — the uplink is chosen per site, not per batch.
- IP68 sealing, 84 months of stored totals and automatic recovery after a power failure are what make it survive an unmanned site.
One transit-time platform, from DN15 to DN300
The measuring core does not change with the bore. Two transducers fire pulses with and against the flow; the difference in transit time gives velocity, velocity times section gives flow. What changes between a DN15 service meter and a DN300 main meter is the body around that core: threaded ends and a compact housing at the small end, a cast flanged spool piece at the large end.
That is why the photographs in this article show the DN15 build — the sealed electronics, the stainless-steel wetted body and the LoRaWAN module are the same family of parts that sit on top of the bulk body. If you are buying for a distribution main, read the specifications below as the bulk series; if you are buying for a building, the DN15–DN50 compact pages cover the same technology in a smaller shell.

1. Which diameters are available, and what are they for?
The LXCY-50~300 series covers nominal diameters from DN50 to DN300 with standard flange connections. It is designed for main pipeline metering rather than household billing, and turns up in water utilities, waterworks, industrial water distribution and agricultural irrigation projects — indoors in a plant room, or outdoors in a chamber on the main.
The practical selection question is not the pipe size but the flow profile: a main sized for peak demand spends most of its life at a fraction of Q3, so the ratio matters more than the maximum. Section 3 covers that.
2. Which standards does it comply with, and how accurate is it?
The series is built to ISO 4064 and OIML R49, at Class 2 metrological accuracy. The bulk range uses an R160 ratio, which keeps the meter inside its error band across a wide spread of flows — the point being that a main does not flow at one rate: it drops to night leakage for eight hours, then climbs to peak demand, then drops again.
For a utility, that stability is the difference between metering and estimating. Meters that lose accuracy at low flow do not lose it visibly; they lose it in the water balance, as non-revenue water that nobody can attribute to a district.
3. What communication options does it support?
Both wired and wireless paths are available, because a utility rarely has one reading method across its whole network. A plant room with a SCADA cabinet wants a cable; a rural main 15 km from the nearest substation wants a radio.
| Wired | M-Bus (EN 13757); RS485 with EN 13757 or Modbus-RTU protocol; pulse output |
|---|---|
| Wireless | LoRa, LoRaWAN (865 MHz / 868 MHz / 915 MHz / 902 MHz and other bands), NB-IoT, 4G cellular, wM-Bus, Sigfox |
| Integration | Open protocol docking, so the meter can be brought into an existing water management platform rather than a new one |
One caveat worth stating plainly: the module is chosen when the meter is ordered. A mixed fleet is normal, but a single batch with a single uplink is cheaper to commission and easier to keep firmware-aligned.
4. What is the protection rating, and where can it be installed?
IP68 — dust-tight and able to stay submerged without water reaching the electronics. Ambient temperature runs from −20 °C to 55 °C; the media side covers cold water at 0.1–50 °C and hot water at 0.1–90 °C.
In practice that covers outdoor installation, underground meter pits and the kind of site where a mechanical meter would need a dry well to survive. A flooded chamber becomes a reading rather than a service visit.

5. Does it need straight pipe runs before and after?
Less than a mechanical meter of the same bore, and less than most buyers expect. The meter installs horizontally or vertically, and the ultrasonic flow field is designed to be insensitive to upstream disturbance: U0/D0 for DN50–DN200 and U10/D5 for DN250–DN300.
Translated into construction terms: on the smaller bulk sizes there is no straight-pipe requirement beyond normal good practice, and on the largest sizes the upstream requirement is about ten diameters. On a retrofit where the chamber is already built, that difference decides whether the project needs civils work at all.
6. How is it powered, how long does the battery last, and what happens in a power failure?
A high-capacity lithium battery, with a service life of ≥10 years in normal operation and a maximum design life of up to 15 years.
The failure behaviour matters more than the headline number. On power loss the meter writes the accumulated flow total and its timestamp to non-volatile memory, and resumes metering automatically when power returns — no manual reset, no lost interval, no site visit from a technician with a laptop.
7. How much history does it keep?
84 months — seven years — of accumulated flow with matching time records. That is long enough to close an annual water balance against the same meter twice, and to go back through a district's history when a discrepancy appears, without relying on the utility's own archive.
There are no moving parts in the measuring path, so there is no wear to explain a drift. Friction sensitivity is low by construction, which is why the accuracy curve at year five looks like the accuracy curve at commissioning.
8. Ultrasonic versus mechanical: what actually changes?
| Measuring element | No impeller or gear train, so nothing wears and nothing is slowed by grit |
|---|---|
| Range | Wider measuring range (R160 on the bulk series) and higher sensitivity at small flow |
| Pressure loss | Lower than a mechanical meter of the same bore — pumping energy is not spent turning a rotor |
| Accuracy over time | Stable, because there is no mechanical wear path |
| Remote reading | Built in rather than retrofitted, including leak monitoring and digital management |
| Whole-life cost | Lower total cost of ownership: less maintenance, fewer disputes, better non-revenue-water control |
If the alternative on the tender is mechanical rather than ultrasonic, the vertical Woltmann table is the one that gets compared — rotor axis, the ratios the standard fixes, and where R200 stops holding ±2 %: reading a vertical Woltmann datasheet.

9. What should go on the enquiry?
Six lines get a quotation that does not come back with questions:
- Bore and connection — DN, flange standard and pressure rating.
- Flow range — minimum night flow and peak demand, so the ratio can be checked rather than assumed.
- Media — cold or hot water, and the actual temperature range.
- Uplink — M-Bus, RS485 (which protocol), pulse, LoRaWAN band, NB-IoT or 4G.
- Installation — chamber, plant room or outdoor, and whether the pipe can be shut down for the swap.
- Documents — the test certificate and declaration you need for the tender.
Related reading
DN50 bulk ultrasonic meter
What the specification sheet leaves out, and why it shows up at commissioning.
Electromagnetic meters, DN40 to DN300
Conductivity, grounding and the range ratio you actually get to choose.
Vertical Woltmann meters, DN32 to DN200
Reading the flow table when the pipe runs vertically.
Sources: LXCY-50~300 Remote Ultrasonic Water Meter User Manual and the LXCY-50~300 series specification sheets, Shenzhen Xingyuan Intelligent Meter Co., Ltd. Figures quoted are the manufacturer's published values; confirm the ratio, flange drilling and protocol against the drawing for your project before ordering.
Read next: Ultrasonic water flow meter — what it measures, where it fits, and what to put on the spec sheet