Bulk ultrasonic · DN50–DN300

LXCY-50~300 bulk ultrasonic water meter, DN50 to DN300

A four-channel transit-time meter built as a flanged pipe section for distribution mains and plant rooms. Class 2 bidirectional measurement, 1.6 MPa body, IP68 sealing, and one communication module per meter — RS485 / M-BUS, or 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN.

DN50–DN300 bore range Class 2 ISO 4064 1.6 MPa PN16 body IP68 protection Four-channel measurement
LXCY-50~300 bulk ultrasonic water meter, DN80 flanged body with bolted ends
DN80, flanged
How it measures

Four channels across the pipe section


On DN50 and above the meter uses four measuring paths instead of one. Averaging four chords flattens the effect of an uneven velocity profile — the swirl and asymmetry you get downstream of a bend or a partly closed valve — so the reading stays stable on a real distribution main, not just on a test bench.

Measuring principleTransit-time ultrasonic, four-channel, bidirectional
AccuracyClass 2, designed and manufactured to ISO 4064; factory inspection to ISO/IEC 17025
Range ratioR400 and R250 across the range; R50 / 63 / 80 / 100 / 125 / 160 / 315 / 500 / 630 / 800 by custom order
BodyIntegral cast-iron flanges to ISO 4064; bolted both ends, so the meter drops into the line as a spool piece
InstallationAny orientation; flow-field sensitivity U0/D0
SealingIP68, whole meter
AlarmsEmpty pipe, reverse flow, leakage, low battery, transducer fault
Flow parameters

Capacity by bore


Q4 is the overload flow the meter must survive briefly, Q3 the rated flow. Both are identical at R400 and R250 — only the bottom of the accuracy band moves with the ratio.

ModelQ4
m³/h
Q3
m³/h
Q1 at R400
L/h
Q1 at R250
L/h
DN5050.040.0100.0160.0
DN6550.040.0100.0160.0
DN8078.7563.0157.5252.0
DN100125.0100.0250.0400.0
DN125200.0160.0400.0640.0
DN150312.5250.0625.01000.0
DN200500.0400.01000.01600.0
DN250787.5630.01575.02520.0
DN3001250.01000.02500.04000.0

Q1 is the bottom of the accuracy band and follows the ratio you order: Q3 ÷ 400 for R400, Q3 ÷ 250 for R250, with Q2 = 1.6 × Q1 as set by ISO 4064. Tell us the ratio and the quotation states Q1 and Q2 for every bore.

Maximum permissible error: ±2 % between 0.1 °C and 30 °C, ±3 % above 30 °C, across Q2 ≤ Q ≤ Q4.

Physical & environmental

Site conditions


Accuracy classClass 2
Temperature classT30, T50
Maximum allowable pressure1.6 MPa
Pressure loss classΔp16
Installation orientationArbitrary
Flow-field sensitivityU0/D0
Reverse flowMeasured and totalled
Environment classClass O
Electromagnetic environmentE2
Protection gradeIP68
Flange standardISO 4064 integral cast-iron flanges; special specifications stated at order
Electronics & communication

Same register, same alarms, one module


Power supply3.6 V lithium battery
Battery life≥8 years on timed upload (reading every 20 min, upload every 12 h)
Wired interfacesRS485 / M-BUS
Wireless interfaces2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN
Local interfaceInfrared port for on-site debugging and parameter setting
DisplayLCD with function symbols
Data retentionHistorical data kept more than 10 years after power loss
Minimum / maximum reading0.1 L / 999,999.9999 m³, rolling over to 99,999,999.99 m³
Dimensions

Flange and face-to-face data


L is the face-to-face length, W the flange outside diameter, H the overall height over the register. All figures in millimetres.

BoreLW
flange Ø
HD1
bolt circle
Bolts
DN502002251651254 × M16
DN652002301851454 × M16
DN802252402001608 × M16
DN1002502502201808 × M16
DN1252502502201808 × M16
DN1503003102852408 × M20
DN20035036034029512 × M20
DN25045041039535012 × M20
DN30050045044540012 × M20

Dimensions and weights are for reference and subject to the actual product. Ask for the certified drawing before fabrication.

Ordering

What to specify


Bore and ratio set the hydraulics; the rest is connection and network.

BoreDN50, 65, 80, 100, 125, 150, 200, 250 or 300 — or give us peak and minimum flow and we will size it
RatioR400 or R250 as standard; other ratios by custom order
CommunicationRS485, M-BUS, 2G, 4G Cat.1, NB-IoT, LoRaWAN or Wi-SUN — one module per meter
Pressure1.6 MPa (PN16) as standard; state the line rating if higher
ConnectionISO 4064 flanges; state any other drilling standard at order

The nine questions buyers ask about this range — which diameters exist, how the U0/D0 straight-pipe rule applies, how much history the meter keeps and what changes against a mechanical unit — are answered in our DN50–DN300 bulk meter guide.

Questions we get asked

Before you specify


Measured and totalled. The meter is four-channel and bidirectional, so backflow appears in the register instead of being treated as zero.

1.6 MPa (PN16) as standard, with a pressure-loss class of Δp16. Tell us the line rating if it is higher.

Integral cast-iron flanges to ISO 4064, bolted at both ends, so the meter drops into the line as a spool piece. Any other drilling standard is stated at order.

A minimum reading of 0.1 L and a maximum of 999,999.9999 m³, rolling over to 99,999,999.99 m³. Historical data is kept for more than 10 years after a power loss.