A 2-inch meter for the point where a building or a district starts paying for water. Full-bore flow path with no moving parts, an EN 1092 four-hole flange that bolts straight onto a standard DN50 spool, and Q3 25 m³/h at R400 — measured both ways and reported over LoRaWAN 915 MHz.
Model LXCY-50. Flange drill, pressure class and body material are confirmed at order — if your pipe runs a different flange standard, tell us before the order and we match it.
| Model | LXCY-50 |
|---|---|
| Nominal size | DN50 (2") |
| Connection | EN 1092 flange, 4 bolt holes |
| Pressure rating | PN16 — 1.6 MPa |
| Pressure loss class | Δp40 |
| Q3 (nominal flow) | 25 m³/h |
| Q4 (overload flow) | 31.25 m³/h |
| Q1 (minimum flow) | 62.5 L/h |
| Q2 (transitional flow) | 100 L/h |
| Measuring ratio | R400 |
| Accuracy | ±2% (0.1–30 °C) |
| Protection grade | IP68 |
| Medium temperature | -25 to +55 °C |
| Body material | Stainless steel / copper / plastic — per configuration |
| Flow path | Full-bore, no moving parts |
| Transducer ports | Machined brass |
| Enclosure | Sealed electronics head, cable glands and cable supplied |
| Communication | LoRaWAN 915 MHz (channel selectable) |
| Flow direction | Bidirectional metering |
| Design & manufacture | ISO 4064 |
| Factory inspection | ISO/IEC 17025 |
| Self-diagnostic alarms | 12 types |
| Data retention | Over 10 years after power loss |

Half the body is cut away here, which is the fastest way to answer the question every buyer asks: what is actually in the water path? The answer is nothing that moves.

Standard DN50 bolt pattern. The meter becomes part of the pipe run instead of an adapter assembly.
Threaded brass transducer housings, machined rather than cast — a clean seat for the sensor and a joint that resists corrosion.
Gasketed lid, screws at every corner and tamper seals. The board never sees the water or the pit humidity.
Glands are fitted at the factory and the cable is supplied with the meter, so commissioning does not stall on a missing part.

The body carries a satin coating over cast metal, the ports are machined brass, and the electronics sit in a sealed IP68 enclosure. Body material is specified per market — stainless steel, copper or plastic — because what is acceptable in one water network is not in another.
The meter joins a LoRaWAN gateway and reports across the district network. The channel is selectable, so one stock model can be set to the plan your network operator runs instead of being ordered against a fixed frequency.


Design and manufacture follow ISO 4064; factory inspection follows ISO/IEC 17025 procedures. For a utility, the second half is what matters — it means the unit you receive was measured, not just assembled.
Alarms include empty pipe, low battery, leakage, reverse flow and transducer fault.

DN50 is the size where a single meter starts carrying a whole building's bill. The flanged body takes the line load, the bore stays clean after a repair, and the LoRaWAN uplink puts the total in the billing system without a site visit.
Why the two-channel head and the R400 bottom end matter in district metering and irrigation — and what the specification sheet leaves out — is set out in the DN50 specification walk-through.

A DN50 is not a parcel you can drop in a carton. Units ship in a wooden crate, and the cable set and glands travel with the meter rather than arriving separately.
The same ultrasonic platform covers DN32 and DN40 bodies, and the industrial DN80 for plant lines.

The series overview: DN32, DN40 and DN50 bodies, 4-channel transit-time measurement, LoRaWAN / NB-IoT / RS-485.

Industrial 3" body for plant water lines and buried chambers, with NB-IoT uplink and Modbus to the panel.
Yes — EN 1092, four bolt holes, PN16. If your pipe uses another pattern (ANSI, JIS, or a different pressure class), tell us at inquiry stage: the flange is machined into the body, so the pattern is set at production, not with an adapter.
At Q3 25 m³/h, R400 puts Q1 at 62.5 L/h — low enough to see night flow at a building inlet, which is where a leak shows up first. If you do not need that resolution, a lower ratio is cheaper and equally accurate in band.
We publish the accuracy figure and the temperature band it applies to — ±2% across 0.1–30 °C — rather than a class label alone, because the label does not tell you where the error starts to rise. The product is designed and manufactured to ISO 4064.
The channel is selectable at configuration. Tell us the plan your network operator runs when you order, and confirm whether you want field re-configuration access for later changes.
Yes — accumulated data is retained for over 10 years after power loss, so a battery or supply interruption does not reset the register.
It is the pressure-loss class: the meter is specified to a Δp of 40 at Q4 in the ISO 4064 sense. In practice a full-bore ultrasonic body loses far less head than an impeller meter of the same size.
Stainless steel, copper or plastic, depending on your water chemistry and the local specification. Send the water conditions and the standard your utility applies and we will confirm the material.
Send the flange standard, pressure class, flow range, body material and the LoRaWAN plan you run. You get the dimension drawing, protocol document and pricing in one reply.