liz@xy-meter.com +86 135 1067 5597 Mon–Sat 08:30–18:00 GMT+8
CE CNAS L25773 ISO 9001
Applications

Water meter applications, from service line to plant inlet

Four families cover the whole water path. What changes between them is pipe size, pressure class and how the reading gets out of the ground.

Residential ultrasonic water meter with valve
01 · Residential & commercial

Revenue metering at the service connection

DN15–DN25 is where a utility's revenue and its water loss both live. The XY series measures from trickle flow upward, so a leaking cistern is visible on the register instead of hiding below the starting flow of a mechanical meter.

  • R400 turndown for small-flow and night-flow detection
  • Remote open / close for prepaid and credit control
  • IP68 housing for cellars and outdoor cabinets
Non-magnetic water meter for pits and damp locations
02 · Difficult sites

Where magnets and water are both a problem

Some markets carry a specific risk: a magnet on the cover, or a pit that floods every rainy season. The LXSY addresses both — non-magnetic registration and an IP68 housing — without asking you to change the reading network.

  • Non-magnetic sensing, immune to external fields
  • Rated for damp, buried and flooded installations
  • Six-year battery with daily reporting
Bulk ultrasonic meter for district metering
03 · Municipal DMA

District metering that survives a main repair

After a repair, debris travels down the main and the first meter it meets is the bulk meter. A mechanical impeller wraps and under-reads for months before anyone notices. An ultrasonic bore has nothing to wrap around, and four measuring channels keep the total stable in a disturbed profile.

  • DN32 / DN40 / DN50, R400, 4-channel measurement
  • LoRaWAN / NB-IoT for chambers without power, RS-485 where there is
  • 8-year battery, IP68 sealed unit

For a DN50 boundary meter specifically — the two-channel head, the R400 bottom end and what the crate contains — read the DN50 specification walk-through.

DN80 ultrasonic meter on a plant water line
04 · Industrial

Plant lines, process water and cooling make-up

In a plant the meter is part of the process, not just the bill. The DN80 flanged body bolts into an existing pipe spool, gives a consumption figure for reporting and a Modbus reading for the control room from the same device.

  • DN80 cast metal body, flanged both ends
  • Modbus to PLC / SCADA, NB-IoT to cloud
  • Nothing inside to clog — pressure loss stays low
Water meter installed in a buried chamber
05 · Buried chambers

Read from the office, not from the pit

The most expensive reading is the one that needs a van, a key and a torch. Every family in the range can report over a mobile network on its own battery, so a chamber that is hard to reach stops being a reason to skip a cycle.

  • No mains power run into the chamber
  • Sealed housing and gland-sealed cable entry
  • Alarms on leakage, reverse flow and empty pipe
Selection

Which family belongs on which site


The same duty is served by different hardware depending on who reads the data and what the site does to the meter. This is the mapping we use when a project arrives as a list of addresses rather than a model number.

Site and sizeFamily that fitsWhat actually decides it
Residential service connection, DN15–DN25DN15 ultrasonic, or the XY-15 valve-control where the utility needs remote shut-offLow-flow accuracy decides the revenue; check the Q3/Q1 ratio for the household draw, not the peak
Apartment blocks and landlord sub-metering, DN15–DN25LXSY non-magnetic or the LXCY-15~50Magnetic tampering and meter-room access; both are solved by the sensing principle, not by the housing
Estate or campus main, DN50–DN80DN50 flanged, DN65 dual-channel or DN80 in-lineFlange standard and straight-run space usually decide this, not the electronics
District metering area (DMA), DN80–DN300LXCY-50~300Night-time minimum flow is the number the whole leak programme rests on, so low-flow stability matters more than Q3
Plant process water and cooling make-up, DN50–DN300LXCY-50~300 with RS-485 / Modbus or M-BusWired output into the plant controller; battery and radio are liabilities here, not features
Irrigation and bulk transfer, DN80–DN300LXCY-50~300 with the multi-channel tubeSuspended solids and a short straight run are the normal case, not the exception

Sizes and families are taken from the current product range. Ratios and Q3 values per family are on the ultrasonic meter range and specifications.

Site conditions

Six things about the site that change the answer


These come up in almost every project review, and each one can move the selection by a family or by a size step. Answer them before the model code is fixed, not after the first delivery.

When a meter misreads on site, the cause is usually one of these six rather than the meter itself: what the readings look like when each one goes wrong.

Questions that come up at selection stage

Rarely well. A DN15 at a household connection and a DN200 on a district main have different failure modes and different budget owners. What can be common is the uplink, the register model and the head-end integration — and that is where the savings actually are.

Yes, per meter. Utilities do it when part of the network is already covered by a LoRaWAN gateway and part is not. The constraint is on the head-end: it has to speak both protocols while keeping one register model across them. The uplink guide sets out who owns the network in each case.

From the flow range you actually measure, not from the pipe diameter. A meter sized to the pipe is usually oversized for the flow, which costs accuracy at the low end where most of the volume is counted. The sizing guide works through Q3, Q4 and the ratio; the calculator does the arithmetic.

Pipe size and material, the normal and peak flow, the water temperature range, whether the pit floods, what the uplink has to reach, and the accuracy class your regulator requires. Six lines is enough; we answer with a model, a drawing and the document set for that model.

System level

AMR, AMI and the head-end you already run


Meters are half a project. The other half is the reading network and the billing system. Our AMR / AMI segment covers data collection and monitoring, and we publish the telegram and register map so your integration team can validate the interface before the volume order.

Your case

Describe the site, we select the meter

Pipe size, pressure, water quality, installation position and the head-end you run — that is enough for us to recommend one model instead of a range.

Choose your language

Interface translated. Technical documents stay in English.