Four families cover the whole water path. What changes between them is pipe size, pressure class and how the reading gets out of the ground.

DN15–DN25 is where a utility's revenue and its water loss both live. The XY series measures from trickle flow upward, so a leaking cistern is visible on the register instead of hiding below the starting flow of a mechanical meter.

Some markets carry a specific risk: a magnet on the cover, or a pit that floods every rainy season. The LXSY addresses both — non-magnetic registration and an IP68 housing — without asking you to change the reading network.

After a repair, debris travels down the main and the first meter it meets is the bulk meter. A mechanical impeller wraps and under-reads for months before anyone notices. An ultrasonic bore has nothing to wrap around, and four measuring channels keep the total stable in a disturbed profile.
For a DN50 boundary meter specifically — the two-channel head, the R400 bottom end and what the crate contains — read the DN50 specification walk-through.

In a plant the meter is part of the process, not just the bill. The DN80 flanged body bolts into an existing pipe spool, gives a consumption figure for reporting and a Modbus reading for the control room from the same device.

The most expensive reading is the one that needs a van, a key and a torch. Every family in the range can report over a mobile network on its own battery, so a chamber that is hard to reach stops being a reason to skip a cycle.
The same duty is served by different hardware depending on who reads the data and what the site does to the meter. This is the mapping we use when a project arrives as a list of addresses rather than a model number.
| Site and size | Family that fits | What actually decides it |
|---|---|---|
| Residential service connection, DN15–DN25 | DN15 ultrasonic, or the XY-15 valve-control where the utility needs remote shut-off | Low-flow accuracy decides the revenue; check the Q3/Q1 ratio for the household draw, not the peak |
| Apartment blocks and landlord sub-metering, DN15–DN25 | LXSY non-magnetic or the LXCY-15~50 | Magnetic tampering and meter-room access; both are solved by the sensing principle, not by the housing |
| Estate or campus main, DN50–DN80 | DN50 flanged, DN65 dual-channel or DN80 in-line | Flange standard and straight-run space usually decide this, not the electronics |
| District metering area (DMA), DN80–DN300 | LXCY-50~300 | Night-time minimum flow is the number the whole leak programme rests on, so low-flow stability matters more than Q3 |
| Plant process water and cooling make-up, DN50–DN300 | LXCY-50~300 with RS-485 / Modbus or M-Bus | Wired output into the plant controller; battery and radio are liabilities here, not features |
| Irrigation and bulk transfer, DN80–DN300 | LXCY-50~300 with the multi-channel tube | Suspended solids and a short straight run are the normal case, not the exception |
Sizes and families are taken from the current product range. Ratios and Q3 values per family are on the ultrasonic meter range and specifications.
These come up in almost every project review, and each one can move the selection by a family or by a size step. Answer them before the model code is fixed, not after the first delivery.
When a meter misreads on site, the cause is usually one of these six rather than the meter itself: what the readings look like when each one goes wrong.
Rarely well. A DN15 at a household connection and a DN200 on a district main have different failure modes and different budget owners. What can be common is the uplink, the register model and the head-end integration — and that is where the savings actually are.
Yes, per meter. Utilities do it when part of the network is already covered by a LoRaWAN gateway and part is not. The constraint is on the head-end: it has to speak both protocols while keeping one register model across them. The uplink guide sets out who owns the network in each case.
From the flow range you actually measure, not from the pipe diameter. A meter sized to the pipe is usually oversized for the flow, which costs accuracy at the low end where most of the volume is counted. The sizing guide works through Q3, Q4 and the ratio; the calculator does the arithmetic.
Pipe size and material, the normal and peak flow, the water temperature range, whether the pit floods, what the uplink has to reach, and the accuracy class your regulator requires. Six lines is enough; we answer with a model, a drawing and the document set for that model.
Meters are half a project. The other half is the reading network and the billing system. Our AMR / AMI segment covers data collection and monitoring, and we publish the telegram and register map so your integration team can validate the interface before the volume order.
Pipe size, pressure, water quality, installation position and the head-end you run — that is enough for us to recommend one model instead of a range.