LoRaWAN, NB-IoT, RS485 or M-Bus: choosing the uplink for a metering fleet

The measuring tube is the same across most of our range. What differs is how the reading leaves the pit — and that decision outlives the meter, because the head-end system will still be running when the meters are replaced.

The options

Six uplinks, and who carries the data


Four of them move the reading over the air; two keep it on a cable. The distinction that matters at procurement is not the radio technology — it is who owns and funds the network after commissioning.

Short answer Six uplinks are covered here: four wireless (LoRaWAN, NB-IoT, 4G Cat.1, Wi-SUN) and two wired (RS-485 / Modbus, M-Bus). The wireless half also has its own category page: wireless water meter.

Uplinks covered6 — 4 wireless, 2 wired
WirelessLoRaWAN, NB-IoT, 4G Cat.1, Wi-SUN
WiredRS-485 / Modbus, M-Bus
Deciding questionWho owns and funds the network after commissioning

Figures from the specification table below · Last updated

UplinkWhat carries the dataWho runs the networkFits when
LoRaWANA gateway you or the utility own; the meters join itYou, or the utilityMany meters in a small area, and someone to run the gateway
NB-IoTThe mobile operator's network, one subscription per meterThe operatorNo gateway, meters spread across a city
4G Cat.1The mobile network, with a larger data allowanceThe operatorMore than one reading a day, or over-the-air updates
Wi-SUNA mesh between meters and a collectorYou, or the utilityDense clusters that should heal around a failed node
RS485 / ModbusA cable to a local controllerThe site ownerPlant rooms, skids, an existing BMS
M-BusA two-wire bus that also powers the meterThe site ownerBuilding metering with an M-Bus master already installed
The decision

Three questions, asked in this order


Unit price is the last thing to compare. These three settle the architecture, and the architecture is what the utility lives with for a decade.

Short answer Three questions settle the architecture before unit price is compared: who owns the gateway, who pays the SIM in year eight, and how many reads a day the fleet actually needs.

Questions that settle the design3
Normal read rate for revenue metering1 per day
Cost basis to compareTotal over the fleet’s life, not the first invoice

Figures as stated on this page · Last updated

4G Cat.1 belongs in the same conversation when you need more than meter readings on the link — firmware updates, valve commands or diagnostics pulled on demand.

Battery

The ten-year figure is a budget, not a property of the cell


Every upload costs radio time, and radio time is what drains the cell. The ten-year figure on our datasheets is tied to a daily upload schedule — change the schedule and you have changed the number.

Short answer The ten-year battery figure is quoted at one upload a day; change the read interval and the number changes with it.

Battery life on the datasheet10 years
Interval that figure assumes1 upload per day
What shortens itMore reads a day, retries at the edge of coverage, valve operations
Valve-control modelsThe motor dominates the budget, not the radio

Figures as stated on this page · Last updated

Wired

Where a cable still wins


RS-485 / Modbus and M-Bus are not legacy options. In a plant room, a basement with a controller, or a retrofit where the cable already exists, they remove the battery, the radio and the subscription in one decision.

Short answer Two wired options still win in plant rooms and retrofits — RS-485 / Modbus and M-Bus — because they remove the battery, the radio and the subscription in one decision.

Wired protocols covered2 — RS-485 / Modbus, M-Bus
Power on M-BusSupplied by the bus — no cell to replace
Best fitPlant rooms, skids, retrofits where the cable already exists

Figures as stated on this page · Last updated

Commissioning

What the utility will ask for before the first reading arrives


Most integration delays are documents, not hardware. We issue these with the quotation so the head-end team can start before the meters ship.

Short answer Five documents decide whether the first reading lands on time: register map, pulse weight, join method and keys, APN and addressing, time and tariff handling.

Documents issued with the quotation5
Usual cause of integration delayDocuments, not hardware
When they are issuedWith the quotation, before the meters ship

Figures as stated on this page · Last updated

The range

Which family carries which uplink


Taken from the current specification table. The module is an order option on most families — confirm the combination you need when the model code is fixed.

Short answer Eight meter families are covered here, and on most of them the uplink module is an order option — the combination is fixed together with the model code.

Families listed8
LoRaWAN onlyDN50 flanged
NB-IoT with ModbusDN80 in-line
Widest uplink choiceDN15 LoRaWAN and XY-15 / XY-20 valve control — 4 wireless plus RS-485 / M-Bus

Figures from the specification table below · Last updated

FamilyUplink options
DN15 LoRaWAN ultrasonicLoRaWAN / NB-IoT / 4G Cat.1 / Wi-SUN, plus RS-485 / M-Bus
XY-15 / XY-20 valve controlLoRaWAN / NB-IoT / 4G Cat.1 / Wi-SUN, plus RS-485 / M-Bus
LXSY-15 / 20 / 25 non-magnetic4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN
LXCY-32~50 remoteLoRaWAN / NB-IoT
DN50 flangedLoRaWAN
DN65 two-channelLoRaWAN / NB-IoT / 4G / RS485
DN80 in-lineNB-IoT with Modbus
LXCY-50~300 bulk4G / LoRaWAN / RS485

Details per protocol, including the models that carry a module as standard: LoRaWAN water meter and NB-IoT water meter.

Questions that come up before the order

Short answer Four questions cover most pre-order objections: gateway ownership, SIM cost across ten years, whether the module changes accuracy, and mixing uplinks in one fleet.

Questions answered4
Effect of the module on accuracyNone — metrology is set by the tube and the electronics, not the radio
Mixing uplinks in one fleetYes, per meter; the head-end has to speak both protocols

Figures as stated on this page · Last updated

Do I need my own gateway for LoRaWAN?
Yes. LoRaWAN is a network you or the utility own: the meters join a gateway, and the gateway needs power, backhaul and someone to look after it. If nobody will take that on, NB-IoT is the honest answer even where LoRaWAN is cheaper per meter.
What does a SIM cost over ten years?
We do not quote operator tariffs — those are negotiated between you and the operator. Ask for a ten-year M2M rate rather than a monthly retail plan, because the subscription outlives the meter's first battery and is usually the largest running cost in an NB-IoT fleet.
Does the module change the accuracy or the approval?
No. Accuracy class, Q3 and the ratio are set by the measuring tube and the electronics that drive it, not by the radio. Adding or changing an uplink module does not move the metrology.
Can one fleet mix uplinks?
Yes, per meter. Utilities do it when part of a network has gateways and part does not. The constraint is on the head-end: it has to speak both protocols and keep one register model across them.
Not sure which meter fits

Send us the pipe size and the protocol you run

We will come back with one recommended model, the wiring diagram and a quotation — not a 40-page catalogue.