Wireless uplink · 865 / 868 / 915 / 902 MHz

LoRaWAN water meter: DN15 to DN300 on a network you own

A LoRaWAN meter reports to a gateway you control, not to an operator's core network. Where that gateway already exists — a campus, a district, a plant with a concentrator on the roof — it removes the SIM, the subscription and the coverage argument, and leaves the reporting interval as the only thing standing between you and a ten-year battery.

Which models carry a LoRaWAN module

One module per meter, chosen at order. The table below is what each range is specified with today — it is not a universal list, because two models in the range do not offer LoRaWAN at all.

RangeUplink options as specifiedLoRaWAN
DN15 ultrasonic4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUNYes
DN50 flangedLoRaWAN 915 MHz, channel selectableYes — 915 MHz
DN65 two-channelLoRaWAN, NB-IoT, 4G Cat.1Yes
DN80 in-lineNB-IoT uplink + Modbus (RS-485)No — NB-IoT only
LXCY 15–502G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUNYes
LXCY 50–3002G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUNYes
LXSY non-magnetic4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUNYes
XY-15 valve control4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUNYes

Wired options run alongside: RS-485 and M-BUS on most ranges, Modbus RTU and CJ/T-188 on DN65.

When a tender asks for turbine and ultrasonic side by side at DN15–DN25 — body material, battery life at one or two transmissions a day, and the payload document — the trade-offs are set out in our DN15–DN25 selection guide.

LoRaWAN or NB-IoT: one question decides it

Not cost, not chipset, not what the last tender asked for. The question is whether there is a gateway on site.

If the site has neither a gateway nor reliable cellular coverage in the chamber, no module fixes that. Commission a signal survey before the meters are ordered, not after they are buried.

Choosing the other side of that question? Signal at the pit, metal chambers, SIM lifecycle and what the meter does while the network is down are set out in the NB-IoT water meter guide.

Bands, and what to put in the order

The LoRaWAN module is built for 865, 868, 915 or 902 MHz. State the band on the purchase order — it is not something that can be corrected in the field, and a 915 MHz unit shipped into a 868 MHz network is a return shipment.

The DN50 flanged meter is specified as LoRaWAN at 915 MHz with channel selection. If your network runs a different plan, say so before the order rather than at commissioning.

For Brazil specifically — AU915-928, Anatel, DN20 sizing, and what “Class B” actually refers to — read the Brazil LoRaWAN guide.

What decides whether you get ten years

The ten-year figure is a battery statement at 25 ± 5 °C with a normal reporting cycle. Three things move it:

Low temperature also costs capacity, which matters if the chamber sees frost.

What does not change across the range

AccuracyClass 2, ISO 4064
ProtectionIP68, whole meter including the cable gland
Battery3.6 V lithium, ≥ 10 years on the DN15 build at 25 ± 5 °C
Local port9600 bps, 8 data bits, even parity, 1 stop bit — quote this to whoever configures the head end
ModulesOne per meter, fixed at order
DN15 LoRaWAN ultrasonic water meter installed on a 1/2 inch pipe

Questions that come up before the order

Does every model offer LoRaWAN?
No. The DN80 in-line meter is NB-IoT with a Modbus local bus, and the DN50 flanged meter is LoRaWAN at 915 MHz specifically. Everything else in the range can be ordered with a LoRaWAN module.
Can a LoRaWAN meter work without a gateway?
No. LoRaWAN is a gateway network by definition — if there is nothing to receive the frame, the meter has nowhere to send it. That is the case for NB-IoT, which reaches the operator's network directly.
Which band should I order?
Whichever your network runs: 865, 868, 915 or 902 MHz. It is fixed at build, so state it on the order.
How long does the battery really last?
Ten years on the DN15 build at 25 ± 5 °C with a normal reporting cycle. A shorter interval, weak signal or a cold chamber all reduce it — give us the interval and we quote against it.
Can it be installed in a metal cabinet?
No. RF does not leave a metal enclosure. This is the single most common reason a working meter never reports.
Can I read the meter on site without a gateway?
Yes. Every range carries a local serial port at 9600 bps, 8 data bits, even parity, 1 stop bit, and the wired models add RS-485 or M-BUS. The radio is one way out of the meter, not the only one — give the port settings to whoever configures the head end.

Still weighing uplinks? LoRaWAN, NB-IoT, RS485 or M-Bus — how to choose one sets out who owns the network, who pays the SIM, and what the battery budget really allows.