A LoRaWAN meter reports to a gateway you control, not to an operator's core network. Where that gateway already exists — a campus, a district, a plant with a concentrator on the roof — it removes the SIM, the subscription and the coverage argument, and leaves the reporting interval as the only thing standing between you and a ten-year battery.
One module per meter, chosen at order. The table below is what each range is specified with today — it is not a universal list, because two models in the range do not offer LoRaWAN at all.
| Range | Uplink options as specified | LoRaWAN |
|---|---|---|
| DN15 ultrasonic | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| DN50 flanged | LoRaWAN 915 MHz, channel selectable | Yes — 915 MHz |
| DN65 two-channel | LoRaWAN, NB-IoT, 4G Cat.1 | Yes |
| DN80 in-line | NB-IoT uplink + Modbus (RS-485) | No — NB-IoT only |
| LXCY 15–50 | 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| LXCY 50–300 | 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| LXSY non-magnetic | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| XY-15 valve control | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
Wired options run alongside: RS-485 and M-BUS on most ranges, Modbus RTU and CJ/T-188 on DN65.
When a tender asks for turbine and ultrasonic side by side at DN15–DN25 — body material, battery life at one or two transmissions a day, and the payload document — the trade-offs are set out in our DN15–DN25 selection guide.
Not cost, not chipset, not what the last tender asked for. The question is whether there is a gateway on site.
If the site has neither a gateway nor reliable cellular coverage in the chamber, no module fixes that. Commission a signal survey before the meters are ordered, not after they are buried.
Choosing the other side of that question? Signal at the pit, metal chambers, SIM lifecycle and what the meter does while the network is down are set out in the NB-IoT water meter guide.
The LoRaWAN module is built for 865, 868, 915 or 902 MHz. State the band on the purchase order — it is not something that can be corrected in the field, and a 915 MHz unit shipped into a 868 MHz network is a return shipment.
The DN50 flanged meter is specified as LoRaWAN at 915 MHz with channel selection. If your network runs a different plan, say so before the order rather than at commissioning.
For Brazil specifically — AU915-928, Anatel, DN20 sizing, and what “Class B” actually refers to — read the Brazil LoRaWAN guide.
The ten-year figure is a battery statement at 25 ± 5 °C with a normal reporting cycle. Three things move it:
Low temperature also costs capacity, which matters if the chamber sees frost.
| Accuracy | Class 2, ISO 4064 |
| Protection | IP68, whole meter including the cable gland |
| Battery | 3.6 V lithium, ≥ 10 years on the DN15 build at 25 ± 5 °C |
| Local port | 9600 bps, 8 data bits, even parity, 1 stop bit — quote this to whoever configures the head end |
| Modules | One per meter, fixed at order |

Still weighing uplinks? LoRaWAN, NB-IoT, RS485 or M-Bus — how to choose one sets out who owns the network, who pays the SIM, and what the battery budget really allows.
Send the model, the band (865 / 868 / 915 / 902 MHz) and the reporting interval. You get the module specification, the frame document and pricing in one reply.
Interface translated. Technical documents stay in English.