NB-IoT puts the meter on the licensed cellular network. There is no concentrator to power, no backhaul to arrange and nothing on site to fail — which is exactly what a scattered set of chambers in a city needs. The trade is coverage: a meter in a basement is only as reachable as the network is at that pit.
One module per meter, chosen at order. Note the gap in the table: the DN50 flanged meter is specified as LoRaWAN at 915 MHz, so NB-IoT is not an option on that model.
| Range | Uplink options as specified | NB-IoT |
|---|---|---|
| DN15 ultrasonic | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| DN50 flanged | LoRaWAN 915 MHz, channel selectable | No — LoRaWAN only |
| DN65 two-channel | LoRaWAN, NB-IoT, 4G Cat.1 | Yes |
| DN80 in-line | NB-IoT uplink + Modbus (RS-485) | Yes — standard fit |
| LXCY 15–50 | 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| LXCY 50–300 | 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| LXSY non-magnetic | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
| XY-15 valve control | 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN | Yes |
The deciding question is whether there is a gateway on site. If there is not, and the chambers are spread across a city, NB-IoT is the shorter route: the meter reaches the operator's network directly and there is no site infrastructure to commission.
Where a gateway already exists and is well maintained, LoRaWAN keeps the data on your own network and removes the subscription. Both are available on most of the range — the choice is a site decision, not a product tier.
Everything below is cheaper to establish now than after the chambers are closed.
A normal reporting cycle gives ≥ 10 years on the DN15 build at 25 ± 5 °C. Three things move that number, and two of them are specific to a cellular uplink:
The fault table in the manual lists four things to check when reporting stops: the SIM, the base station or core network, the IoT platform, and the battery. Work down that list before replacing a cell.
| Accuracy | Class 2, ISO 4064 |
| Protection | IP68, whole meter including the cable gland |
| Battery | 3.6 V lithium, ≥ 10 years on the DN15 build at 25 ± 5 °C |
| Local port | 9600 bps, 8 data bits, even parity, 1 stop bit |
| Storage | 24 months of monthly totals, 100 daily totals, 100 alarms; totals survive a power loss |

Still weighing uplinks? LoRaWAN, NB-IoT, RS485 or M-Bus — how to choose one sets out who owns the network, who pays the SIM, and what the battery budget really allows.