Not sure this is the right bore? Work it out from your peak and minimum flow — the sizing calculator needs two numbers.

A register that cannot be talked to with a magnet. The LXSY reads by non-magnetic sensing, so the classic revenue attack — a magnet held against the cover — does nothing. Sealed to IP68 and built for pits that fill with water.
The LXSY is a configurable platform: brass or stainless housing, several ratio options and four uplink choices are set at order. Send the site conditions and we return the exact model code.
| Model | LXSY-15 / LXSY-20 / LXSY-25 |
|---|---|
| Nominal size | DN15 / DN20 / DN25 |
| Accuracy class | Class 2, ISO 4064 design |
| Sensing | Non-magnetic, immune to external magnetic fields |
| Protection | IP68 — damp, buried and flooded sites |
| Battery | 3.6 V lithium, ≥6 years with daily reporting |
| Uplink | 2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN, plus IR for on-site configuration |
| Installation | No straight pipe run required |
| Housing | Brass / stainless steel, configured to order |
| Options | Valve control, pulse output, custom dial and marking |
Three ratio options sit on the same measuring unit. Q3 is the permanent flow, Q1 the smallest flow the meter must still register, and R is their ratio.
| Nominal size | Ratio R (Q3/Q1) | Overload Q4 (m³/h) | Permanent Q3 (m³/h) | Transitional Q2 (m³/h) | Minimum Q1 (m³/h) |
|---|---|---|---|---|---|
| DN15 | R160 | 3.125 | 2.5 | 0.025 | 0.016 |
| R125 | 0.032 | 0.020 | |||
| R100 | 0.040 | 0.025 | |||
| DN20 | R160 | 5 | 4 | 0.040 | 0.025 |
| R125 | 0.051 | 0.032 | |||
| R100 | 0.064 | 0.040 | |||
| DN25 | R160 | 7.875 | 6.3 | 0.063 | 0.039 |
| R125 | 0.081 | 0.050 | |||
| R100 | 0.101 | 0.063 |
Minimum resolution 0.0001 m³; maximum cumulative volume 99999.9999 m³. Maximum permissible error ±5% in the low zone (Q1 ≤ Q < Q2) and ±2% in the high zone (Q2 ≤ Q ≤ Q4).
With the remote module fitted. L is the overall length, L1 the body length between the union nuts, H the height including the module.
| DN (mm) | L (mm) | L1 (mm) | W (mm) | H (mm) | Thread | Weight (kg) |
|---|---|---|---|---|---|---|
| DN15 | 165 | 135 | 100 | 125 | G3/4B | 1.20 |
| DN20 | 195 | 135 | 100 | 125 | G1B | 1.35 |
| DN25 | 225 | 135 | 100 | 135 | G1 1/4B | 2.05 |
Taken from the current LXSY-15~25 manual. Values apply to all three sizes unless a range is given.
Last updated . Ask us for the full manual or the register map — both go out with the quotation.
| Temperature class | T30 / T50 / T70 |
|---|---|
| Working pressure | 0.03–1.0 MPa |
| Max. allowable pressure | 1.6 MPa |
| Pressure loss | ΔP ≤ 0.063 MPa |
| Protection grade | IP68 |
| Electromagnetic environment | Class E2 |
| Environment class | Class O |
| Flow field sensitivity | U0 / D0 — no straight pipe run required |
| Operating temperature | −20 °C to +50 °C |
| Storage temperature | −40 °C to +70 °C |
| Measurement error | ±5% (Q1 ≤ Q < Q2); ±2% (Q2 ≤ Q ≤ Q4) |
| Housing material | Cast iron / stainless steel / brass |
| Power supply | 3.6 V DC lithium battery |
| Battery life | ≥ 6 years at daily reporting |
| Standards | ISO 4064 design; factory inspection to ISO/IEC 17025 |
| Reading success rate | 99.99%+ with automatic retransmission |
No magnetic coupling between the measuring element and the register, so an external magnet cannot freeze or reverse the count.
IP68 sealing with a gasketed cover: a pit that floods in the rainy season does not end the meter's life or the reading.
A 3.6 V lithium pack with daily reporting. Longer intervals extend life further; the reporting profile is fixed with you at order.
4G Cat.1, NB-IoT, LoRaWAN or Wi-SUN on the same platform, so one stock model can serve several markets.
A reed switch still responds to a strong external magnet. Non-magnetic sensing does not use magnetic coupling at all, so a magnet held to the cover has no effect on the register.
The housing is IP68 sealed and specified for damp, buried and flooded sites. For chambers that flood regularly, we recommend the version with the sealed cable gland and remote antenna option.
No. The LXSY is designed for short service lines where a straight run upstream is not available.
Yes. Caliber, housing and network are configured to order, so a single purchase order can carry LoRaWAN for one district and NB-IoT for another.
Tell us the DN mix, the network you run and how often you need a reading. We reply with a model code, battery estimate and price.
Interface translated. Technical documents stay in English.