liz@xy-meter.com +86 135 1067 5597 Mon–Sat 08:30–18:00 GMT+8
CE CNAS L25773 ISO 9001
Download this datasheet (PDF) All eight datasheets

Not sure this is the right bore? Work it out from your peak and minimum flow — the sizing calculator needs two numbers.

ISO 4064 design Class 2 IP68 No straight pipe required
Residential · Non-magnetic

LXSY-15 / 20 / 25 Non-Magnetic Remote Water Meter

A register that cannot be talked to with a magnet. The LXSY reads by non-magnetic sensing, so the classic revenue attack — a magnet held against the cover — does nothing. Sealed to IP68 and built for pits that fill with water.

DN15 / DN20 / DN25Nominal size
Class 2Accuracy
≥6 yearsBattery life
IP68Sealed housing

Compare meters →

  • Immune to magnetic interference — no magnetic coupling in the register
  • Rated for damp cellars, buried boxes and flooded pits
  • Daily reporting on a six-year battery
  • Caliber, housing and network configured to order
Specification

Technical data


The LXSY is a configurable platform: brass or stainless housing, several ratio options and four uplink choices are set at order. Send the site conditions and we return the exact model code.

ModelLXSY-15 / LXSY-20 / LXSY-25
Nominal sizeDN15 / DN20 / DN25
Accuracy classClass 2, ISO 4064 design
SensingNon-magnetic, immune to external magnetic fields
ProtectionIP68 — damp, buried and flooded sites
Battery3.6 V lithium, ≥6 years with daily reporting
Uplink2G / 4G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN, plus IR for on-site configuration
InstallationNo straight pipe run required
HousingBrass / stainless steel, configured to order
OptionsValve control, pulse output, custom dial and marking
Metrology

Flow parameters by ratio


Three ratio options sit on the same measuring unit. Q3 is the permanent flow, Q1 the smallest flow the meter must still register, and R is their ratio.

Nominal sizeRatio R (Q3/Q1)Overload Q4 (m³/h)Permanent Q3 (m³/h)Transitional Q2 (m³/h)Minimum Q1 (m³/h)
DN15R1603.1252.50.0250.016
R1250.0320.020
R1000.0400.025
DN20R160540.0400.025
R1250.0510.032
R1000.0640.040
DN25R1607.8756.30.0630.039
R1250.0810.050
R1000.1010.063

Minimum resolution 0.0001 m³; maximum cumulative volume 99999.9999 m³. Maximum permissible error ±5% in the low zone (Q1 ≤ Q < Q2) and ±2% in the high zone (Q2 ≤ Q ≤ Q4).

Dimensions

Face-to-face length and thread


With the remote module fitted. L is the overall length, L1 the body length between the union nuts, H the height including the module.

DN (mm)L (mm)L1 (mm)W (mm)H (mm)ThreadWeight (kg)
DN15165135100125G3/4B1.20
DN20195135100125G1B1.35
DN25225135100135G1 1/4B2.05
Full specification

Technical data


Taken from the current LXSY-15~25 manual. Values apply to all three sizes unless a range is given.

Last updated . Ask us for the full manual or the register map — both go out with the quotation.

Temperature classT30 / T50 / T70
Working pressure0.03–1.0 MPa
Max. allowable pressure1.6 MPa
Pressure lossΔP ≤ 0.063 MPa
Protection gradeIP68
Electromagnetic environmentClass E2
Environment classClass O
Flow field sensitivityU0 / D0 — no straight pipe run required
Operating temperature−20 °C to +50 °C
Storage temperature−40 °C to +70 °C
Measurement error±5% (Q1 ≤ Q < Q2); ±2% (Q2 ≤ Q ≤ Q4)
Housing materialCast iron / stainless steel / brass
Power supply3.6 V DC lithium battery
Battery life≥ 6 years at daily reporting
StandardsISO 4064 design; factory inspection to ISO/IEC 17025
Reading success rate99.99%+ with automatic retransmission
Design notes

Made for the pits nobody wants to open


Magnet-proof registration

No magnetic coupling between the measuring element and the register, so an external magnet cannot freeze or reverse the count.

Submersible housing

IP68 sealing with a gasketed cover: a pit that floods in the rainy season does not end the meter's life or the reading.

Six years on one cell

A 3.6 V lithium pack with daily reporting. Longer intervals extend life further; the reporting profile is fixed with you at order.

Four networks, no redesign

4G Cat.1, NB-IoT, LoRaWAN or Wi-SUN on the same platform, so one stock model can serve several markets.

Questions we get asked

Before you specify


A reed switch still responds to a strong external magnet. Non-magnetic sensing does not use magnetic coupling at all, so a magnet held to the cover has no effect on the register.

The housing is IP68 sealed and specified for damp, buried and flooded sites. For chambers that flood regularly, we recommend the version with the sealed cable gland and remote antenna option.

No. The LXSY is designed for short service lines where a straight run upstream is not available.

Yes. Caliber, housing and network are configured to order, so a single purchase order can carry LoRaWAN for one district and NB-IoT for another.

Next step

Get the LXSY quotation

Tell us the DN mix, the network you run and how often you need a reading. We reply with a model code, battery estimate and price.

Choose your language