LoRaWAN water meters for Brazil: AU915, Anatel and sizing
A commercial-building tender from São Paulo landed on the desk with eleven technical lines. Six of them decide whether the meter works; three of them are usually written in a way that gets the wrong product back. This is what each line actually means, and what to ask before you sign a purchase order.
The tender asked for a DN20 multi-jet meter, accuracy Class B or C, no display, an integrated S0 pulse output and a LoRaWAN module locked to the Brazilian bands. Four of those requirements pull against each other, and the reason is worth understanding before the first quotation arrives — because a supplier who says “yes” to all of them is either not reading carefully or not telling you everything.
A DN15 ultrasonic unit of the type used as the reference in this article.What sits under the cover: register, IR port for local setup, battery compartment, threaded ends.
AU915-928 is a factory decision, not a setting
Brazilian deployments run on the AU915-928 plan, and the regulator permits short-range devices in defined sub-bands rather than across the whole 915 MHz neighbourhood. A LoRaWAN radio is built for one regional parameter set: the channel plan, the dwell-time rules and the maximum output power are set by the firmware image, not by a menu.
That is why the requirement “the device must not be capable of operating outside these bands” is the right one to write — and why the answer has to be a factory statement, not a configuration note. Ask for it in writing, per model, and check that the certificate or test report names the same frequency plan.
Remote reading, remote configuration and alarms all ride on the same module.IP68 is the rating that lets a meter live in a vault rather than a cabinet.
DN20 is a starting point, not a calculation
The tender asked for Qmin ≥ 30 L/h and Qmax ≥ 5 m³/h on a DN20 body. Those two numbers already tell you the bore is being used as a shorthand for a flow range, and the shorthand is worth checking: at DN20 a meter is typically rated around Q3 4 m³/h, which sits under the 5 m³/h peak the building is expected to draw.
Size on the peak, then confirm the bottom of the range. A meter chosen for the peak alone will still measure at night, but it will sit near its transitional flow where accuracy is loosest — and a commercial building's night flow is exactly where a leak hides. The practical sequence is: peak flow → nearest standard Q3 → check that Q1 is below your expected night flow → only then fix the bore.
Q4 — overload flow
The highest flow the meter must survive briefly without damage. Size above your worst case, not at it.
Q3 — permanent flow
The flow the meter is rated for continuously. This is the number that should sit above your design load.
Q2 — transitional flow
Where the accuracy band changes. Below it the tolerance widens.
Q1 — minimum flow
The bottom of the accuracy band. Compare against measured night flow, not against a guess.
R — Q3 ÷ Q1
The range ratio. R200 is common; R400 extends the bottom end by a factor of two.
Multi-jet or ultrasonic
The tender said multi-jet, which is the default for commercial buildings because it needs no power for the measuring element. But the same tender also asked for battery power, IP68 and a radio module — once you are running a battery and a module anyway, the argument for a mechanical element gets weaker, not stronger.
Multijet meters are cheap and well understood, and they keep working when the electronics do not. Their weakness is the impeller: grit wears it, scale fouls it, and the error drifts slowly downward at low flow — the direction that costs the utility money and nobody notices for years. An ultrasonic meter has nothing in the water path to wear, and it measures reverse flow as a signed quantity rather than ignoring it.
Feature, advantage, benefit, evidence — the same four questions a tender should ask.Stainless steel in SS304 or SS316, threaded, rated to 2.5 MPa on request.
Where the two types actually differ: a multi-jet meter fails by drifting — slowly, quietly, always downward. An ultrasonic meter fails by stopping — loudly, immediately, with an alarm. For a building owner reading a bill, the second failure is easier to fix.
“No display” usually costs more than it saves
The tender asked for no LCD. The intention is sound — fewer openings, fewer failures, nothing for a passer-by to read — but a meter with no local display and no local interface has to be commissioned, checked and diagnosed over the radio, by someone who is not standing at the meter.
A register that shows cumulative volume, instantaneous flow, water temperature and operating hours turns a site visit into a two-minute check. An infrared port does the same job for parameter setting without opening the housing — which is the point on an IP68 unit, because every time you break the seal you gamble on the gasket.
Six readings and five alarms on one screen — the difference between a diagnosis and a guess.How the flow figures stack up on a DN15 unit: Q4 3.125, Q3 2.5, Q2 0.020, Q1 0.0125 m³/h.
If the pulse output is what the building management system actually needs, keep it — but keep the display too. The two are not alternatives. A pulse output compatible with S0-style inputs (EN 62053-31 pattern, 24 V, short pulse) suits a controller that counts edges; the display suits the technician who has to prove the counter is telling the truth.
Brass, plastic or stainless steel
The tender allowed brass or plastic “NSF/potable water approved”. Both are reasonable; what matters more is the water and the installation. Brass machines to a thread that seals without tape and tolerates the chlorides in municipal supply. Engineering plastic removes the corrosion path entirely and suits aggressive or soft water. Stainless steel in 304 or 316 removes body corrosion as a failure mode for the life of the meter, at a price that only makes sense when the tender names the material or the water is genuinely hostile.
Whichever body you choose, the thread standard has to be stated: BSP for most of Europe and much of South America, NPT for North America. A DN20 meter with the wrong thread is a meter with a site problem on the day it arrives.
IP68 is a whole-meter claim
The tender asked for IP68, which is the right call for a pit or a vault. The distinction that gets missed in quotations is scope: an IP68 register on an IP65 body is not an IP68 meter. The rating has to cover the cable gland, the seal around the cover, and the terminal compartment — because water finds the lowest-grade opening, not the highest.
Ask for the rating to be stated as a whole-unit claim, and ask whether the same rating applies with the antenna fitted. An external SMA connector is a sealed joint only if it is designed as one; an internal antenna avoids the question entirely.
Class B, Class C and Class 2
The tender asked for accuracy Class B or Class C to ISO 4064. Both are legacy designations. Under the current edition of ISO 4064 the accuracy classes A, B and C were replaced by class 2 for a meter of this type, and class 2 is what appears on a nameplate and a test report issued today.
A supplier who says “yes, Class C” is either quoting an old certificate or translating an old requirement. The question to ask instead: what does the current test report state, and does it cover the bore you are buying? If your national authority still references Class B, say so at order and ask for the test report to be read against that requirement — that is a documentation task, not a different meter.
Five years is a floor, and the interval sets it
The tender asked for a minimum of five years of battery life and an upload interval configurable from one to five minutes. Those two numbers pull against each other. Every transmission costs energy, and a one-minute interval is twelve times the radio work of a twelve-minute interval. A cell that lasts five years reporting hourly will not last five years reporting every sixty seconds.
So the answer to “how long does the battery last” is only meaningful with the interval attached. On the reference unit here, the published figure is ten years or more at 25 ±5 °C — and that figure carries the same condition. Ask any supplier what reporting interval their number assumes, and what happens to it at your interval.
Q4 / Q3
3.125 / 2.5 m³/h on a DN15 unit; the DN20 and DN25 bodies in the same family sit higher
Range ratio
R200 standard; R400 available as a custom configuration
Accuracy
Class 2 to ISO 4064
Temperature class
T30, T50 or T70 by order
Working pressure
1.0 MPa (PN10) standard; 1.6 MPa option; up to 2.5 MPa on request
Protection
IP68, whole unit
Power
3.6 V lithium cell; ten years or more at 25 ±5 °C
Communication
LoRaWAN standard; RS485, M-BUS, 2G/4G, NB-IoT or Wi-SUN optional
Ambient range
−25 to +55 °C
Five things people call “certification”
The tender listed ISO 9001, OIML R49 or ISO 4064, and CE. These are three different kinds of document, plus one the tender did not list but that matters more than any of them in Brazil.
Document
What it actually certifies
Who issues it
ISO 9001:2015
The factory's quality management system, not the product
An accredited certification body
ISO 4064 / OIML R49
The metrological performance of the meter type, tested to the standard
A test laboratory, ideally accredited
CE marking
Market access for the applicable directives, declared by the manufacturer
The manufacturer, via a declaration of conformity
Anatel homologation
Permission for the radio to transmit in Brazil — per model, and separate from everything above
The Brazilian regulator, applied for in Brazil
An ISO 9001 certificate says nothing about the product. A CE declaration does not prove a radio is legal in Brazil. And Anatel homologation is not something a supplier can substitute with a CE or FCC certificate — it is applied for in Brazil, per model. Confirm who holds it before the goods ship, because a LoRaWAN meter that is not homologated is a meter that has to sit in a warehouse.
The eight answers worth demanding
A quotation that answers these eight questions is a quotation you can compare. One that answers six of them is a quotation that will produce a change order.
1. Model and datasheet
The exact model number plus a PDF that states Q1, Q2, Q3, Q4 and the ratio — not a range table from a catalogue
2. Price at 4 and at volume
Sample price for four units, and the price at your target annual volume, with the MOQ stated
3. ISO 9001 certificate
A valid copy with a certificate number that can be checked against the issuing body
4. Frequency bands
The exact band written on the radio's test report, and confirmation that AU915-928 is one of them
5. Regional lock
A factory statement that the unit cannot be configured outside the permitted bands — in writing, per model
6. Battery figure
The years, the ambient temperature the figure assumes, and the reporting interval it assumes
7. Lead time and freight
Sample lead time in working days, plus a DAP quote to your city with the Incoterm and the HS code
8. Anatel status
Whether homologation exists for this model, and if not, who is expected to apply for it
Commercial buildings are the case where sizing on peak flow alone goes wrong.
Questions buyers ask
Yes, and it should be. A LoRaWAN radio is built per regional parameter set at the factory, so the band is a firmware and bill-of-materials decision rather than a user setting. Ask for the statement in writing, per model, and match it against the test report.
Only if your peak flow sits under the DN20 rated flow. A building expecting 5 m³/h at peak is usually better served by DN25, and the cost difference is small compared with a meter running near its overload limit.
Yes. It is a separate approval from CE, FCC or ISO 4064, it is granted per model, and it is applied for in Brazil. Confirm before shipping who holds it — the manufacturer or your Brazilian importer.
Current certificates state class 2 under the present ISO 4064 edition. Class B and C come from earlier editions of the standard. If your authority still uses those terms, tell us at order and the test report is read against that requirement.
Range depends on gateway height, antenna gain, building density and the meter's installed position — a figure quoted for open field says little about a basement vault. Share the gateway location and the site plan, and the link budget can be checked rather than assumed.
It is not necessary for reading, and it is very useful for commissioning and fault-finding. The display and the radio are not alternatives; keeping both costs almost nothing and saves site visits.
Send the tender, not the summary
Pipe size, flow range including night flow, water temperature, the frequency plan, the platform it must talk to, and the destination port. You will get a quotation that answers the eight questions above rather than a catalogue page.