Most specification sheets answer the wrong question. They list a diameter and a price, and leave out the two facts that decide the outcome: what the water does to the body, and what the pipe does to the measurement. Everything below is organised around those two questions, using the FABE structure — feature, advantage, benefit, evidence — so the reasoning behind each number is visible rather than implied.
Four families, one plant
We build four meter types. They overlap in size but not in purpose, and a buyer who mixes them up usually ends up paying for capability the site never uses — or losing accuracy where it matters.
| Family | Sizes | Measurement | Connection | Typical duty |
|---|---|---|---|---|
| Ultrasonic, threaded | DN15–DN25 (1/2″–1″) | Transit-time, no moving parts | Threaded | Apartment and building inlet, prepaid or AMR |
| Ultrasonic, flanged | DN32–DN300 | Transit-time, two or four channel | Flanged | District mains, plant rooms, bulk transfer |
| Multi-jet mechanical | DN15–DN80 | Multi-jet impeller | Threaded to DN40, flanged above | Utility billing where no power or network exists |
| Valve control and prepaid | DN15–DN25, 3/4″ control units | Ultrasonic or multi-jet plus motorised valve | Threaded | Prepaid, RFID card, remote shut-off |
Materials: what each one is for
Body material is not a cost decision dressed up as an engineering one. Each of the four materials we use answers a specific water condition, and choosing the wrong one shows up as pitting, dezincification or stress cracking years after installation.
Brass — the default for potable water up to DN40
Feature. Dezincification-resistant brass body, machined threads, DN15 to DN40.
Advantage. Brass machines to a clean thread that seals against tapered pipe threads without tape, and it resists the chloride levels found in most municipal supply.
Benefit. Fewer weeps at the joint on commissioning day, and no callbacks for a body that has gone porous in year seven.
Evidence. The multi-jet range is supplied in brass from DN15 to DN40, which is the size band where a utility still installs by hand in a meter box.

Cast iron — the large-size body
Feature. Cast iron body with a protective coating inside and out, DN50 and above.
Advantage. Iron carries the wall thickness and the flange rigidity that a DN80 or DN150 body needs, at a weight and price brass cannot reach in that size.
Benefit. A body that holds its shape under 1.6 MPa line pressure and a flange that does not distort when the bolts are torqued on site.
Evidence. The flanged ultrasonic series uses a carbon steel pipe section with brass transducer ports — iron for structure, brass only where the transducer has to seal.
Plastic and nylon — the small-size and prepaid body
Feature. Engineering plastic and nylon bodies in the small sizes and in the consumer valve-control units.
Advantage. No corrosion path at all, and a body that can be moulded around the valve seat rather than machined into it.
Benefit. A meter for aggressive or soft water where a metal body would scale or corrode, and a control unit light enough to hang on a 3/4-inch line.
Evidence. Plastic and nylon are offered alongside brass and iron in the same small-size range, so the body can be matched to the water chemistry without changing the interface.
Stainless steel — the specification that ends the argument
Feature. Stainless steel body available on request.
Advantage. No coating to scratch, no dezincification, no iron oxide in the water.
Benefit. The choice that survives a water audit and a tender specification that names the material, and the one that removes body corrosion as a failure mode for the next twenty years.
Evidence. Offered as a material option across the range rather than as a separate product line — the same internals, a different shell.
Structure: what is inside the housing
The outside of a water meter is a housing and a dial. The part that decides whether the reading is right is inside: the measuring element, the way it is isolated from the water, and the way the total is stored when the power or the network is gone.
The measuring element
On an ultrasonic meter, two or four transducers face each other across the measuring tube and fire alternately, upstream then downstream. The difference in transit time between the two directions is proportional to flow velocity; the meter converts it to volume. There is nothing in the water path to wear, so grit, scale and low flow do not erode the reading the way they erode an impeller.

On a multi-jet meter, the water is split into several jets that drive a impeller with a balanced load on the bearing. It needs no power, which is exactly why it still wins in locations where no battery or network will ever be maintained.
The register and the display
Totals run to nine digits on the main register with a separate five-digit display for smaller units — a range of 0 to 999,999,999, which is what a DN15 meter needs if it is going to sit on a line for fifteen years without rolling over. The register keeps counting and logging whether or not the network is reachable, so a coverage gap costs readings, never volume.
The valve, where there is one
On the valve-control and prepaid versions, a motorised valve sits in the same body as the measuring element. It closes on credit exhaustion, on a remote command, or on a leakage alarm. The advantage is that shut-off is a metering decision taken by the same device that measures — not a separate valve that can be bypassed.
Sealing
The whole meter is sealed to IP68, including the cable gland where a wired version leaves the housing. That single rating is what allows the meter to live in a wet pit or a buried chamber without a vented enclosure, and it is the difference between a meter that survives a flooded chamber and one that is replaced after it.