A transit-time meter does not count a rotor. It measures how fast the water is moving, multiplies by the bore, and integrates. That is why the reading holds at flows a mechanical meter would miss — and why two things you never had to think about with a turbine decide whether you get a reading at all: whether the pipe is full, and whether the water is carrying air.

What the meter is doing while you install it
Two transducers face each other across the bore. Each fires a pulse; the meter times the difference between the downstream and upstream transit times, derives velocity from that difference, and turns velocity and bore into volume. Nothing rotates, and nothing in the water path wears against the flow.
Two consequences follow, and both matter on site. The first is that a clear bore means very little pressure loss, so the meter does not take head off a marginal system. The second is that the measurement is of velocity in water — so it is only valid while the pipe is full and free of entrained air. A meter asked to measure a half-empty pipe will report a low or zero figure, and it will report it honestly.
The LXCY series is designed and built to GB/T 778-2018, the Chinese national standard for cold and hot potable-water meters, and factory-verified to JJG 162-2019. If you are comparing it against a meter carrying ISO 4064 certification, ask which certificate applies to the market you are selling into — the two answer different questions.
Orientation: the manual gives a ranking, not a list of options
Ultrasonic measurement is not sensitive to the angle of the meter, and the manual allows multi-angle installation without loss of accuracy. That is a statement about accuracy, not about whether a position will work. The four positions below are ranked, and the ranking is about keeping the pipe full.
| Position | Verdict | Why |
|---|---|---|
| Vertical pipe, flow upward (or diagonally upward) | First choice | The water column stays full, and any free air travels up and away from the measuring section |
| Horizontal pipe | Second choice | The manual's fallback position, with no restriction of its own |
| Flow downward (or diagonally downward) | Avoid | The manual's reason is stated plainly: the pipe may not run full |
| The highest point of the run | Do not use | Air collects there, and the manual identifies trapped bubbles as a cause of abnormal measurement |
Two clearances come with the position. Keep the meter at least 50 mm off the wall — you need room for a tool on the union nut and for the optical head at commissioning. And keep it away from magnetic fields.
Two environments are worth ruling out before you order rather than after: acidic atmospheres and heavy salt fog, both of which the manual warns will accelerate ageing of the materials and can take the meter out of the hygiene standard it was supplied against. The same section of the manual asks you not to leave the display panel in direct sun for long periods, which in practice means a pit lid or a shade rather than an open south-facing wall.
The arrow, and why backwards is worse than it looks
The flow-direction mark on the side of the body has to agree with the water. This is the one installation error that does not announce itself with a zero.
The meter is bidirectional. Reverse flow is measured, added to a separate reverse total, and raises a reverse-flow alarm. So a meter fitted the wrong way round is not a meter that reads nothing — it is a meter reading correctly into the wrong register. If the utility bills forward volume, the water passes through and nothing is charged for it, and the only trace is an alarm nobody is watching.
Check the mark against the pipe run before the joint is sealed, not after. On a new connection, crack the upstream valve and let the pipe fill while you are still able to turn the meter.
Threads, sealing, and the two ways to mount it
The manual describes two methods. The difference is whether you bring the meter to the pipe or the pipe to the meter.
- Without coupling fittings. Cut the supply pipe and leave the meter's own length. Align the meter coaxially with the pipe, thread it in, and tighten with a wrench.
- With coupling fittings. Cut the pipe, screw the fittings onto the cut ends first, then mount the meter onto the fittings.
| Nominal size | Meter thread, direct mounting | With coupling fittings |
|---|---|---|
| DN15 | G¾B | R½ |
| DN20 | G1B | R¾ |
| DN25 | G1¼B | R1 |
| DN32 | G1½B | R1¼B |
| DN40 | G2B | R1½B |
The manual's installation note is about the joint itself: seal it, and confirm there is no leak before the pit is closed. Face-to-face length and height differ by size, so ask for the dimensional drawing for the size you are actually installing rather than scaling from another one.
One safety note that reads as boilerplate until it happens: the exposed thread will cut a hand. Gloves, and do not lift the meter by the electronics head — the manual treats it as a precision instrument and asks that it not be dropped or struck.
Signal: the rule that decides how long the battery lasts
This is the part of the manual most often skipped, and it is the part that generates the support tickets six months later. An NB-IoT or 4G Cat.1 meter spends its life asleep and wakes to attach. Every attachment it fails costs it the same current as one it completes.
The manual puts a hard requirement on the installation: the site must sit at signal coverage level 0 or 1, which it defines as signal strength of 25 or better and a signal-to-noise ratio of −30 or better. Below that, two things happen together — the battery life shortens several-fold, and the reporting success rate falls.
The numbers behind that requirement. The radio draws 210 mA while it is attached, 1.8 mA on standby and 18 µA asleep. Between the attach current and the sleep current there is a factor of more than ten thousand. A meter that has to retry its attachment every day lives at the wrong end of that range, and a ten-year battery becomes a two-year battery without a single component failing.
Two more conditions sit in the manual's own warning list. Never install the meter inside a metal enclosure — the enclosure is a shield, and the meter will behave as though it were in a dead spot. And a meter configured to report when there is no base station, no core network or no reachable server shortens its own battery life severely, because every report is retried.
Under normal conditions the reporting period is one day, and the ten-year figure assumes an ambient of 25 ± 5 °C. Outside that band, and wherever resends or frequent alarms occur, take the figure as an upper bound rather than a promise. If the pit is marginal, measure the signal before you buy the meters: no firmware setting fixes a missing base station.
Commissioning: verification mode and the readings to record
The meter has two display modes and the difference is one decimal place in the right direction. From the home screen — the forward accumulated total — press and hold for at least five seconds until the screen changes and the verification symbol appears in the top right. That is verification mode, and it carries six decimal places. It returns to user mode on its own after six hours without a keystroke, or immediately on another five-second press.
In user mode the forward total carries four decimals, with a resolution of 0.0001 m³ and a display range of 0 to 999,999.999 m³. The display is a nine-digit LCD with a light-sensitive button, so there is no key to break or to fill with grit.
Record these seven values at commissioning and put them in the handover file. They are what you will compare against in six months when somebody asks whether a reading is plausible:
- Forward accumulated volume
- Reverse accumulated volume — it should be zero, and a non-zero figure is the fastest confirmation of a reversed body
- Instantaneous flow, with a known draw open
- Water temperature
- Battery voltage
- Date and clock
- Accumulated effective operating hours
The meter stores 24 months of monthly totals, 100 daily totals, 30 periodic-consumption records, 600 water-temperature records, the last 100 daily maximum-flow records and the last 100 alarms, and the totals survive a power loss. The wired or optical link runs at 9600 bps, even parity, 8 data bits, 1 stop bit — quote that to whoever configures the head-end, because it is the one line of the manual the software team actually needs. The whole meter is IP68, including the cable entry, and the storage range is −25 to +55 °C.