Selection guide

Choosing a meter size: Q3, Q4 and the DN you actually need

Every meter in our range is Class 2. What changes with size is not the accuracy class but the flow band the meter can hold — and that band is set by Q3, Q4 and the ratio between them, not by the thread on the pipe.

Definitions

Q1 to Q4, and what each one decides


ISO 4064 gives every meter four flow rates. Three of them set the size you order; the fourth decides whether the meter is useful at three in the morning.

TermDefinitionWhat it decides for you
Q3Permanent flow — the highest rate the meter may run at continuouslyThe size you order
Q4Overload flow — a short-term rate above Q3Whether flushing and transients are covered
Q1Minimum flow — the smallest rate that still registers inside the error bandWhether night flow and small leaks are visible
RQ3 ÷ Q1The resolution of the low end: R160 sees less than R400
MAPMaximum admissible pressureBody, flange and gasket choice

A Class 2 meter holds ±2 % between Q2 and Q3 and ±5 % below Q2. Both limits come from ISO 4064 and are the same on every size — the bore does not change the class.

The rule

Size on Q3, not on the peak you saw once


The number people bring to us is usually a peak: a fire flow, a flushing rate, a pump start. Q4 already covers that as a short-term overload. Sizing the meter on it is how a 3/4" service ends up carrying a 2" meter.

The range

Published Q3 values across our families


These are the standard configurations, taken from the current specification table. The same nominal size can be built with a different Q3 and ratio — confirm the exact model against a signed specification sheet before you tender.

FamilyNominal sizeQ3Ratio RUplink
DN15 LoRaWAN ultrasonicDN15 (1/2")On requestR400 – R1000LoRaWAN / NB-IoT / 4G Cat.1 / Wi-SUN
XY-15 / XY-20 valve controlDN15 – DN252.5 / 4.0 / 6.3 m³/hR100 – R400LoRaWAN / NB-IoT / 4G Cat.1 / Wi-SUN
LXSY-15 / 20 / 25 non-magneticDN15 – DN252.5 / 4.0 / 6.3 m³/hR160 – R4004G Cat.1 / NB-IoT / LoRaWAN / Wi-SUN
LXCY-32~50 remoteDN32 – DN5016 / 25 / 40 m³/hR400LoRaWAN / NB-IoT
DN50 flangedDN50 (2")25 m³/hR400LoRaWAN
DN65 two-channelDN50 – DN15040 m³/hR400LoRaWAN / NB-IoT / 4G / RS485
DN80 in-lineDN80 (3")100 m³/hR250 – R400NB-IoT + Modbus
LXCY-50~300 bulkDN50 – DN300On requestR250 / R4004G / LoRaWAN / RS485

On request means the flow parameters are set during the specification step rather than taken from a catalogue entry — common on DN15 LoRaWAN and on bulk sizes above DN150.

Three starting points

A dwelling, a building, a plant line


The same method lands on very different hardware. These are the ranges most enquiries fall into.

Single dwelling or apartment

Start at DN15 with Q3 2.5 m³/h. If the utility wants night-flow leak detection, the ratio is the deciding number rather than the bore — R160 or better at that size.

Check first: the smallest flow you must register, not the highest.

Building or small commercial

Q3 from 4.0 to 40 m³/h across DN20 to DN50. Pressure loss at Q3 is worth calculating before ordering — a long internal run can cost more head than the meter does.

Check first: pressure loss at Q3 against the head available.

Plant line or district main

DN65 to DN300, Q3 from 40 m³/h upward. Flanged body in every case, and the flange standard has to be confirmed before the spool is fabricated, not after.

Check first: flange drilling standard and straight-pipe requirement.

Where the reading has to leave the site

Once the size is fixed, the uplink decides the rest: LoRaWAN where you own a gateway, NB-IoT where you do not, RS485 or M-Bus where the meter sits in a plant room.

Compare the uplinks →

The trade-off

What a meter that is too big actually costs


Oversizing looks like caution and behaves like a fault. A meter sized for a flow the site never reaches spends its life below Q2, where the error band widens, and much of the time below Q1, where it does not count at all.

Further reading

Where to check the numbers


Three places to go next, depending on whether you already know the flow or only know the pipe.

After installation

If the number still looks wrong


Sizing explains most of what a meter reports, but not all of it. Air, scale and a short straight run produce errors that a correctly sized meter will still show — the failure-mode guide starts from the symptom and works back to the cause.

Questions that come up before the order

Is Q3 the maximum flow a meter can see?
No. Q3 is the permanent flow — the highest rate the meter is rated to run at continuously. Q4 is the short-term overload above it. Both are in the datasheet, but Q3 is the number that sets the size you order.
Should I go one size up to be safe?
Usually not. A larger bore runs slower at the same flow, and below Q1 the register stops counting. Oversizing is the most common reason a meter reads zero in the small hours, when most of the annual volume actually passes.
What ratio do I need for leak detection?
It depends on the smallest flow you must see. R is Q3 divided by Q1, so R160 on a DN15 with Q3 2.5 m³/h resolves down to about 15.6 l/h, while R400 reaches roughly 6.3 l/h. Tell us the leak rate you want to catch and we confirm the ratio rather than the model.
Is the accuracy class different for larger sizes?
No. Every family in our range is Class 2. What changes with size is the flow band and the ratio: R400 to R1000 on the DN15, R100 to R400 on the XY-15/20, R160 to R400 on the LXSY, R400 on the LXCY-32~50, R250 to R400 on the DN80.
Not sure which meter fits

Send us the pipe size and the protocol you run

We will come back with one recommended model, the wiring diagram and a quotation — not a 40-page catalogue.